3.

ADJUSTMENT

3.1
Adjustment of Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-200))
(1)
Install the process unit into the equipment.
Note:
Note:
Do not install the toner cartridge.
(2)
While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
(3)
Key in code [200] and press the [ENTER] button.
The display changes as follows and the "density LEDs" lights from the left in order.
[2][0][0]