Technical
-
Validate the user input.
-
Initialise the SYNC module.
-
Initialise the DISPLAY module.
-
Initialise the MIXER module.
-
Initialise the DENC module.
-
Set the selected video standard.
-
Generate the selected test image in memory.
-
Start the DISPLAY module.
-
Start the MIXER module.
-
Start the DENC module according to the selected test image id.
Execution Time
1 second.
User Input
The user has to decide which test image, video standard and video output must be used:
Test image id:
0
1
2
3
4
5
6
7
8
9
10
Video standard:
PAL
NTSC
Video output:
ALL
CVBS
YC
RGB
YUV
PSCAN
Error
Number
10100
10101
10102
10103
10104
10105
Example
DS:> 101
010100:
Test OK @
DS:> 101 0 pal cvbs
010100:
Test OK @
DS:> 101 4 ntsc yc
010100:
Test OK @
VERTICAL_COLOURBAR (default)
HORIZONTAL_COLOURBAR
WHITE
YELLOW
CYAN
GREEN
MAGENTA
RED
BLUE
BLACK
GRAY
(default)
CVBS and YC and RGB (default)
progressive scan
Description
Generating the test image succeeded.
Invalid input was provided.
The Chrysalis SYNC-module cannot be initialised.
The Chrysalis MIXER-module cannot be initialised.
The Chrysalis VPP-module cannot be initialised.
The Chrysalis DENC-module cannot be initialised.