Dial Tone (Dt) Detection Timer - Panasonic DBS 824 Installation Manual

Digital business system
Hide thumbs Also See for DBS 824:
Table of Contents

Advertisement

FFl
Dial Tone (DT) Detection Timer
Dial Tone (DT) Detection
Timer -
Software Version: CPC-S and CPC-M, Version 1.0 and higher
Address:
FFl 3## 28# (0-255)#
Description
Use this program to set the amount of time (in milliseconds) the DBS 824 will
wait to detect a dial tone from the CO, before
automatically
redialing an
outgoing call. If a dial tone is not detected within this amount of time, auto-
repeat dialing will not be carried out.
Programming
1
FFl 3# 28# (01255)#
+
Timer Setting (Default=25;
see the following table for values)
Table l-31. DT detection timer values
Number
0
1
2
1200 ms
4Oms
80 ms
Value (in milliseconds)
3
120 ms
4 . . . 24
160 ms . . . 960 ms (increments of 40 ms)
25'
1
1,000 ms (or 1,second)
26
I 1,040ms
1
27 . . . 255
1 1,080 ms . . . 10,200 ms (or 10.2 seconds)
Related Programming
Auto-Repeat Dialing Count: FFl 2# l# 34## (O-15&
Wait Timer For Auto-Repeat Dialing: FFl 3# 26# (O-15)1+
Busy
Tone (ST) Detection Timer: FFl 3# 27# (0- 15)##
CO Busy Tone (ST) Detection for Auto-Repeat Dialing: FF2 (Trunk)# 22#
Issued 3/l I95
DBS 824-l O-400
l-115

Advertisement

Table of Contents