Sign In
Upload
Manuals
Brands
GE Manuals
Medical Equipment
MAC 1200 ST
GE MAC 1200 ST Manuals
Manuals and User Guides for GE MAC 1200 ST. We have
2
GE MAC 1200 ST manuals available for free PDF download: Operator's Manual, Service Manual
GE MAC 1200 ST Operator's Manual (200 pages)
Brand:
GE
| Category:
Medical Equipment
| Size: 1.78 MB
Table of Contents
Table of Contents
5
The Basics
13
About this Manual
15
Manual Purpose
15
Intended Audience
16
Definitions
16
Illustrations and Names
17
Revision History
17
Safety Information
18
Definitions
19
Underwriters Laboratories, Inc
22
Biocompatibility
23
Literature
23
Service Information
24
Requirements
24
Controls and Indicators
25
General Information
27
MAC 1200 Control Panels
27
MAC 1200 Keyboard
28
MAC 1200 ST Keyboard
29
Symbols
30
Operating and Performance Tests
31
Power Supply
33
Installation and Mains Connection
34
Performance Check
35
Contrast Adjustment
36
System Setup
37
Connecting Peripheral Equipment
39
Preparing for ECG Recording
41
Connecting the Patient Cable
43
Electrode Application
44
Applying Plate Electrodes (Limbs)
44
Applying Suction Electrodes (Chest)
44
Electrode Placement for Standard Leads (L, II, III, Avr, Avl, Avf, V1
45
Electrode Placement for Nehb Leads
47
Artifact Due to Poor Electrode Application
49
Entering Patient Data
51
New Patient
53
Last Name, First Name
53
Date of Birth
53
Patient ID
53
Chest Pain
54
Pacemaker
54
Gender/Race
54
Height/Weight
54
Systolic Bp/Diastolic BP
54
Ordering Physician / Referring Physician / Technician
54
Phone Number
55
Medication
55
Comments
55
Swedish Patient ID
55
ID Required
55
Secondary ID
56
Secondary ID Required
56
Last/First Name Required
56
Location Number
56
Room
56
Order Number
56
Prompts
56
Automatic Mode Recording
57
General Information
59
Recording
61
The Storage Program
64
Report Formats
66
Detailed Results
67
ECG Transmission
68
General Considerations
68
Batch Transmission
68
Transmission Log
69
Error Messages
69
Transmission to a Cardiosys/Cardiosoft System Via Modem
70
Transmitting Data to a MUSE CV System Via Modem
72
Modem Setup (for Modem Æ Other)
75
Adjusting Measurement Points/Qt Dispersion
77
Global Measurement Points
77
Local T Offset Measurement Point/Qt Dispersion
79
Manual Mode Recording
81
General Information
83
Recording
84
Arrhythmia Mode Recording
87
General Information
89
Recording
91
During the Recording
92
Final Report
94
Stress Tests
97
General Information
99
Stress Test Sequences
102
Ergometers Without Digital Communication Interface
102
Ergometers with Remote Start Pulse
104
Ergometers with Digital Communication Interface
105
Treadmill
108
The Master's Step Test
110
Creating Custom Protocols
113
Running a Stress Test
114
Ending the Stress Test
117
Final Report
118
Pacemaker Patients / Recording During Defibrillation
121
Recording Ecgs of Pacemaker Patients
123
ECG Recording During Defibrillation
124
System Setup
125
General Information
127
Automatic Mode
128
Report Sequence
128
Rhythm Leads
128
Gain
128
Report Format
128
Detailed Results (MAC 1200 / 1200 ST Only)
128
Continuous Rhythm
129
Muscle Filter/Ac Filter
129
Muscle Filter Frequency
129
Manual Copy to
130
Number of Copies
130
Interpretation
130
Print Interpretation
130
Override Function [No]
131
Manual Mode
132
Report Sequence
132
Gain
133
Speed
133
Muscle Filter/Ac Filter
133
Muscle Filter Frequency
133
Anti-Drift System (ADS)
134
Auto Paper Feed
134
Arrhythmia Mode
135
Report Sequence
135
Gain
135
Muscle Filter
135
AC Filter
135
Muscle Filter Frequency
136
Trend Recording
136
Arrhythmia Data
136
Episodes
136
Stress Test Mode
137
Report Sequence
137
Protocol
137
Rhythm Leads
142
Gain
142
Speed
142
In-Test Reports
142
Muscle Filter/Ac Filter
142
Muscle Filter Frequency
143
Maximum HR after
143
J+X Point Formula
143
Calculation (E, J Point)
143
Arrhythmia Data
143
Final Reports
144
System Setup
145
Ordering Physician/Referring Physician/Technician
145
Institution Name
145
Cart Number
145
Site Number
145
Location
146
Date/Time
146
Lead Fail Beep
146
High HR Beep
146
Lead Labels
146
Pace Enhancement
146
Baseline Roll Filter
146
Date
147
Time
147
Units
147
Mains
147
LCD Light off after
147
Low Battery Beep
147
Beep for Master Step
147
Default Mode
148
Language
148
Enable Password Protection
148
Test Data
148
Restore Defaults
148
Print Configuration Lists
148
Transmission Log
149
Check Record Retxn
149
Communication
150
Baud Rate (PC)
150
Protocol
150
Modem
150
PIN Dialing
151
Manual Dialing
151
Ergometer/Treadmill
152
Patient Data Menu Setup
153
Required Data Fields
154
Prompts 1 to 4
154
Option Code
155
ECG Transmission Via Modem
156
Selecting the Communication Protocol
156
Direct ECG Transmission
157
Selecting the Communication Protocol
157
Loading Chart Paper
159
Procedure
161
End-Of-Paper Indication
163
Aging Stability
164
Cleaning, Disinfection and Maintenance
165
Cleaning and Disinfecting the Recorder Housing
167
Cleaning and Disinfecting the Patient Cable
167
Cleaning and Disinfecting the Electrodes
167
Maintenance
168
Checks before each Use
168
Technical Inspections
168
Disposal
168
Troubleshooting
169
Troubleshooting Chart
171
Technical Specifications
173
Recording
175
Printer Paper
175
Paper Transport
175
Membrane Keypad
176
Display
176
Indicators (Leds)
176
Lead Selection
176
Automatic Functions
176
Detection of Pacer Pulses
177
Heart Rate Indication
177
Signal Inputs
177
Data Interface
178
Transfer of Ecgs with the CSI Protocol between the MAC 1200 and the Following Units
178
Receiving Data with the CSI Communication Protocol from the Following Units
178
Sending Ecgs to the Following Units with the A5 Protocol
179
Remote Start (Hardware)
179
Signal Transmission
180
Order Information
185
General Information
187
Options
187
General Accessories
187
Entering Special Characters
191
Special Characters
193
Index
195
Advertisement
GE MAC 1200 ST Service Manual (151 pages)
Resting ECG Analysis System
Brand:
GE
| Category:
Medical Equipment
| Size: 2.11 MB
Table of Contents
Table of Contents
5
1 The Basics
11
About this Manual
13
Manual Purpose
13
Intended Audience
13
Definitions
13
Illustrations and Names
14
Revision History
14
Basic Information
15
Variants of the MAC 1200 Resting ECG Analysis System
16
Hardware Functional Blocks
16
Block Circuit Diagram of Entire Instrument
17
Mechanical Components
18
2 Functional Description
19
Basic Information
21
Switching Power Supply
22
PCB NC Battery Charge
23
Charging Circuit for the NC Battery
23
Battery-Dependent Device Behavior
24
PCB Control CS_CI
25
Generation of Internal Power Supplies
25
Switch On/Off Circuit
26
ECG Recording and Front-End Processing
27
Controller Core
28
Real Time Clock
29
Memory
30
LCD Graphics Display Interface
30
Modem Supply
35
Internal Interfaces
36
Mechanical Interfaces
36
Electronic Interfaces
36
Interfaces to Peripherals
41
Electronic Interfaces
42
Limitations
44
3 System Test Function
45
General Information
47
Test Start
48
Display Test
49
Contrast Control
49
Keyboard Test
50
Motor Test
51
Test Results
52
Self-Test
53
Error Codes
53
Recording Test
54
V24 Tests
55
Sending and Receiving (1)
55
Send Test String to Device (2)
55
Send and Receive with Device (3)
56
Time and Date
57
Electrode Test
58
Time Constant/Baseline Roll Filter
59
Setting the Device Model
60
Interpretation (International Device Models Only)
62
Pace Enhance
63
Serial Number
64
Ergometer / Treadmills (JAPAN Device Model Only)
65
ACI-TIPI (US Device Models Only)
66
Pharma
67
High Security
67
4 Repair Instructions
69
Safety Instructions
71
Replacing Components
72
Opening the Device
72
5 Troubleshooting
79
Basic Information
81
6 Adjustment Instructions
85
Basic Information
87
7 Service and Maintenance
89
Technical Inspections/Preventative Maintenance
91
Visual Check
92
Test Functions
92
Safety Analysis Tests
96
Maintenance, Cleaning, and Disinfection
99
8 Parts List
101
Introduction
103
Field Replaceable Units (Frus)
104
High Level Assemblies
104
9 Specifications
111
Basic Information
113
Recording
113
Printer Paper
113
Paper Transport
114
Membrane Keypad
114
Display
114
Indicators (Leds)
114
Automatic Functions
114
Detection of Pacer Pulses
115
Heart Rate Indication
115
Signal Inputs
115
Data Interface
116
Pin Assignment of Data Port
116
Remote Start (Hardware)
116
Signal Transmission
117
ECG Calibration
118
Automatic ECG Gain Adjustment
118
Baseline
118
Anti-Drift System (ADS) (Cubic Spline)
118
ECG Storage
118
Blocking
119
Electrode Monitoring
119
Text Input
119
Copy Function
119
Test
119
Power Supply
119
Mains Operation
120
Battery Operation
120
Operational Readiness
120
Operating Position
120
Environment
121
Recorder Dimensions
121
Weight
121
10 Drawings
123
Basic Information
124
High Level Assembly, PN 101 168 01
125
11 Drawings
125
High Level Assembly, PN 101 168 01
126
PCB Assembly Drawing, PN 2033914-027
127
Schematic, PN 2033914-033, Sheet 1
128
Schematic, PN 2033914-033, Sheet 2
129
Schematic, PN 2033914-033, Sheet 3
130
Schematic, PN 2033914-033, Sheet 4
131
Advertisement
Related Products
GE MAC 1600
GE MAC 1200
GE marquette MAC 1100
GE MAC 5000
GE MAC 800
GE MAC 2000
GE MAC 5500
GE MAC 5500 HD
GE MAC 3500
GE MAC 600 SPY
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL