Item
Plug-in power supply
unit for the TC35
Terminal
14
Interface description
Interference immunity
• The cable length must not exceed 3 m
• Current carrying capacity < 1.5 A (Western
modular jack)
• Nominal signal range: 0 ... +30 V
• Max. load current 1.5 A
• Electrical fast transient burst
requirements in accordance with
ETS 300-342-1
• Surge immunity requirements in
accordance with ETS 300-342-1
• Electrostatic discharge requirements in
accordance with ETS 300-342-1
• Immunity R. common mode
0.15 – 80 MHz in accordance with
ETS 300-342-1
• Transients and surges in a vehicular
environment
• Voltages dips and interruption
Connectible plug-in power supply unit
Order no. Supplier
39001
Sphere Design
Saarpfalz-Park 10
D-66450 Bexbach Saar
Tel.: +49 6826 / 5200-0
.ax: +49 6826 / 5200-25