TH 192 Pneumatic Room Thermostat
Retrostat Kits

Product Description

The TH 192 Pneumatic Room Thermostat Retrostat
kits convert most existing pneumatic room
thermostats to a Powers™ Controls TH 192 direct or
reverse acting, two-pipe, single setpoint device. This
kit includes a cover that can be configured to
conceal or expose the setpoint adjustments, setpoint
indicator, and thermometer. Also, the kits can
include an optional 1/2-inch large, exposed setpoint
adjustment knob.
Contents
Part
Retrostat Cover Kit
Thermostat *
Hardware kit
Optional 1/2-Inch Large, Exposed
Setpoint Knob
Adapter Frame (192-308)
* Includes thermostat installation instructions.
Product Numbers
Retrostat Kit
(See Notes below)
192-840
Direct Acting Fahrenheit Scale
192-841
Reverse Acting Fahrenheit Scale
192-850
Direct Acting Celsius Scale
192-851
Reverse Acting Celsius Scale
NOTES:
1. Includes all parts needed for all conversions
listed in Table 1 including installations where a
large rough-in hole must be covered. These
installations may require an adapter frame
(192-308).
2. For Retrostat Kits with white cover, order the
standard kit with "W" suffix.
3. For Retrostat Kits with optional 1/2-inch large,
exposed setpoint adjustment knob, order the
standard kit with "K" suffix.
Item Number 129-116, Rev. FA
Quantity
1
1
1
1
1
Type
Installation Instructions
Required Tools
Calibration and cover screw wrench
(192-632) or 1/16" Allen wrench and 1/8"
open-end wrench
Medium flat-blade screwdriver
Small level
Accurate thermometer
Needle nose pliers
Prerequisites
Review all of these instructions before you
begin installation.
Check job drawings for any site-specific
information.
Verify that the existing thermostat installation
has its supply and return air lines connected
properly.
Make certain air supply is 18 to 25 psi
(124 to 172 kPa) normal.
Obtain the installation instructions provided
with the thermostat in the Retrostat Kit. The
document provides instructions for calibrating
the thermostat.
Make certain a supply of wall anchors and
plastic ties are available.
Expected Installation Time
1 hour
Document No. 129-116
September 24, 2009
Page 1 of 12

Advertisement

loading

Summary of Contents for Siemens Retroline TH 192

  • Page 1: Product Description

    Installation Instructions Document No. 129-116 September 24, 2009 TH 192 Pneumatic Room Thermostat Retrostat Kits Required Tools Product Description • Calibration and cover screw wrench The TH 192 Pneumatic Room Thermostat Retrostat (192-632) or 1/16” Allen wrench and 1/8” kits convert most existing pneumatic room open-end wrench thermostats to a Powers™...
  • Page 2: Installation

    Figures 3 through 26. 4. Loosely screw adapter base to the multi-slotted plate. 5. Draw plastic tubing through the multi-slotted plate and the adapter base. Install the plug-in adapters on the wall plate. Page 2 of 12 Siemens Industry, Inc.
  • Page 3 Powers Controls Flush the Powers Universal Adapter Kit (192-300), TH 832D (See Powerstar Thermostat, and Powerstar Note 1) Thermostat. Consult you local Siemens Building Technologies representative for details. Powers Controls Flush box TH 180, TH 182, Surface Place the optional 1/2-inch large setpoint...
  • Page 4 • Thermometer Calibration • Changeover Point Adjustment • Limit Stop Adjustment • Sensitivity Adjustment • Thermostat Cooling/Heating Calibration • Troubleshooting Reference Figure 1. Typical Thermostat Installation. Page 4 of 12 Siemens Industry, Inc.
  • Page 5 3. Mount the cover over the frame and secure in place by turning each end locking screw five turns counterclockwise. Figure 2. TH 192 Installation with Guard. NOTE: Adapter Frame, Adapter Base, and Plug-in Adapter (2) not shown. See Figure 1 for proper installation. Siemens Industry, Inc. Page 5 of 12...
  • Page 6 See Figure 1 for proper installation. Figure 4. TH 180, TH 182, TH 192 Horizontal to Vertical Figure 5. TH 180, TH 182, TH 192 Horizontal to Vertical Flush Installation. Surface Installation. Page 6 of 12 Siemens Industry, Inc.
  • Page 7 Document No. 129-116 Installation Instructions September 24, 2009 NOTE: Plug-in Adapter (2) not shown. See Figure 1 for proper installation. Figure 6. Honeywell TO900A, TP900A Surface Box Installation. Siemens Industry, Inc. Page 7 of 12...
  • Page 8 NOTE: Adapter Base and Plug-in Adapter (2) not shown. See not shown. See Figure 1 for proper Figure 1 for proper installation. installation. Figure 10. Honeywell TO91A, TP901A, B Flush Fitting Figure 9. Honeywell TO91A, TP901A, B Mortar Installation. Joint Installation. Page 8 of 12 Siemens Industry, Inc.
  • Page 9 Adapter (2) not shown. See Figure 1 for proper Adapter (2) not shown. See Figure 1 for proper installation. installation. Figure 14. Honeywell TP970A, B Deep Wall Box Figure 13. Honeywell TP970A, B Shallow Wall Box with Installation. Plaster Ring Installation. Siemens Industry, Inc. Page 9 of 12...
  • Page 10 Figure 18. Johnson T400, 401, 402 Old Round Head. NOTE: Adapter Base and Plug-in Adapter (2) not shown. See Figure 1 for proper installation. Figure 17. Johnson T400, 401, 402 Flush Fitting Installation. Page 10 of 12 Siemens Industry, Inc.
  • Page 11 NOTE: Adapter Base and Plug-in Adapter (2) not shown. See Figure 1 for proper installation. Figure 21. Robertshaw T15, T16, TP2210 Dry Wall Figure 22. Barber Colman TK1001, 1002, 1003, 1101, 1102, Installation. 1103, 9001, 9101 Surface Box Installation. Siemens Industry, Inc. Page 11 of 12...
  • Page 12 Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Retroline is a registered trademark of Siemens Industry, Inc.Powers Controls is a registered trademark of Siemens Industry, Inc.