Summary of Contents for Haier HCR2250ADS

  • Page 1 Installation Instructions Instructions d’installation Instrucciones de instalación HCR2250ADS HCR6250ADS 24” and 36” Dual Fuel Free-Standing Range Cuisinière autoportante à bi-combustible de 24” et 36” Estufa independiente para dos combustibles de 24” y 36”...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS RANGE SAFETY ....................1 INSTALLATION REQUIREMENTS ................. 3 Location Requirements ....................3 Given Dimensions are Minimum Clearances..............4 Electrical Requirements - Canada Only ................ 6 Gas Supply Requirements ..................... 7 INSTALL RANGE ....................10 Install Anti-Tip Bracket ....................10 Electrical Connection ....................10 Gas Connection ......................14 Converting to Different Types Of Gas ................15...
  • Page 4 WARNING Fire Hazard If the information in this manual is not followed exactly, a re or explosion may result causing property damage, personal injury or death. - Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 5: Installation Requirements

    WARNING Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults.
  • Page 6: Given Dimensions Are Minimum Clearances

    IMPORTANT: Some cabinet and building materials are not designed to withstand the heat produced by the oven for baking and self-cleaning. Check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. GIVEN DIMENSIONS ARE MINIMUM CLEARANCES.
  • Page 7 WARNING Electrical Shock Hazard The electrical power to the oven branch circuit must be shut off while line connections are being made. Do not use an extension cord with this appliance. Electrical ground is required on this appliance. The free end of the green wire (the ground wire) must be connected to a suitable ground.
  • Page 8: Electrical Requirements - Canada Only

    ELECTRICAL REQUIREMENTS - CANADA ONLY WARNING Electrical Shock Hazard Electrically ground range. Failure to do so can result in death, re or electrical shock. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge are in accordance with local codes.
  • Page 9: Gas Supply Requirements

    GAS SUPPLY REQUIREMENTS WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a quali ed person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a quali ed person include: licensed heating personnel, authorized gas company personnel, and...
  • Page 10 GAS SUPPLY LINE Provide a gas supply line of 3/4” (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. With LP gas, piping or tubing size can be 1/2”...
  • Page 11: Gas Pressure Regulator

    GAS PRESSURE REGULATOR The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation: Natural gas: Minimum pressure: 5” WCP Maximum pressure: 14” WCP LP gas: Minimum pressure: 11” WCP Maximum pressure: 14”...
  • Page 12: Install Range

    INSTALL RANGE INSTALL ANTI-TIP BRACKET IMPORTANT: • An Anti-Tip Bracket kit is included with the range. Follow the instructions supplied with the anti-tip bracket. • Do not completely remove the rear leveling leg. The anti-tip bracket uses the rear leveling leg to secure the range to the floor. •...
  • Page 13 Power supply cord strain relief • Remove the knockout for the 40-amp supply cord. • Assemble a UL listed strain relief in the opening. • Feed the power supply cord behind the black horizontal cross brace and through the strain relief, allowing enough slack to easily attach the wiring to the terminal block.
  • Page 14 3-WIRE CONNECTION WARNING Electrical Shock Hazard Frame grounded to neutral of appliance through a link Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor.
  • Page 15 Grounded Neutral Junction Box Green Wire Black Wires Red Wires Cable from Oven Cable from Power Supply White Wires U.L. Listed Conduit Connector 4-WIRE CONNECTION • Disconnect ground from neutral at free end of conduit. • Connect the green GROUND wire from the oven to the GROUND wire in the junction box (bare or green colored wire).
  • Page 16: Gas Connection

    ELECTRICAL FEATURES Oven Light 25 W Spit Motor Upper Heating Element 1950 W Bottom Heating Element 1800 W Grill Heating Element 2250S Circular Heating Element 1800 W Ventilator Motor 30 W Cooling Fan 11 W This appliance shall be installed only by authorized persons and in accordance with the manufacturer’s installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, local water supply regulations.
  • Page 17: Converting To Different Types Of Gas

    TYPICAL FLEXIBLE CONNECTION 1. Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters. 2. Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters. 3.
  • Page 18 4. Replace the injectors with those supplied corresponding to the gas available (see Burner and Injector Characteristics table). 5. Replace the various parts proceeding in reverse. When converting from Natural Gas to LPG ensure that the NG regulator is removed and replaced with the Test Point Assembly.
  • Page 19: Abnormal Operation

    ABNORMAL OPERATION ANY OF THE FOLLOWING ARE CONSIDERED TO BE ABNORMAL OPERATION AND MAY REQUIRE SERVICING: • Yellow tipping of the hob burner flame. • Sooting up of cooking utensils. • Burners not igniting properly. • Burners failing to remain lit. •...
  • Page 20 REQUIRED FOR WARRANTY SERVICE IMPORTANT Ne pas Réexpédier ce Produit au Magasin Pour tout problème concernant ce produit, veuillez contacter le service des consommateurs “Haier Customer Satisfaction Center” au 1-877-337-3639. UNE PREUVE D’ACHAT DATEE EST REQUISE POUR BENEFICIER DE LA GARANTIE. IMPORTANTE No regrese este producto a la tienda Si tiene algún problema con este producto, por favor contacte el...