2.
After the login prompt appears, enter "default" for the login name.
login: default
3.
After a message prompting operation of the mode switch appears, operate
the mode switch on the operation panel as follows.
a. Switch the mode switch on the operation panel to the Locked position, and
Change the panel mode switch to Locked and press return... Omitted
b. Leave the switch in that position for at least 5 seconds.
Leave it in that position for at least 5 seconds.
c. Return the mode switch to the Service position, and press the RETURN key.
Change the panel mode switch to Service and press return...
Omitted
Note - Complete this switching operation of the mode switch in 1 minute or less. If the
operation exceeds 1 minute, login authentication times out.
4.
Confirm that the system management terminal displays the XSCF shell prompt.
XSCF>
Note - The following message may be output after login for a building block configuration:
"XSCF firmware update now in progress. BB#xx,please wait for XSCF firmware update
complete." If so, the XCP firmware version is automatically being matched.
Execute the showlogs monitor command to confirm the message of "XCP firmware version
synchronization completed," and then perform the next work.
6.4
Checking the XCP Version
This section describes the procedure for checking the XCP version.
In a building block configuration of the M10-4S, all the chassis must have the same
XCP version. Confirm the XCP versions. If any chassis has a different version, update
press the RETURN key.
Chapter 6 Performing an Initial System Diagnosis
183