Trobleshooting - LG GC-W061 series Service Manual

Table of Contents

Advertisement

TROBLESHOOTING

5. Trobleshooting
5-1. COMPRESSOR AND ELECTRIC COMPONENTS
1
Power Source
Check the
2
resistance of the
Compressor Motor.
Check the
resistance of
3
the PTC.
4
Check OLP.
Check the starting
5
state.
Separate the PTC-STARTER from the
Compressor and measure the voltage
between M and C of the Compressor.
The applied voltage is not in the range
of Rating Voltage ± 10%.
Test the resistance among
M-C, S-C, and M-S.
NO
Replace the Compressor.
Test the resistance of the both
terminals in the PTC-STARTER.
Check if applying a
regular OLP.
YES
NO
Measure minimum starting voltage
after checking steps 1-3 above.
Measure the pressure balance of the
PTC at the interval of more than 5 min.
Starts at the voltage of more
than 90%.
Equal to the applied
voltage. (Rating
voltage ± 10%)
Advice the customer to
use in the specified
range.
If not 0 or
Replace the
NO
PTC-STARTER.
Advice the customer to use
in the specified range.
Starts at the voltage
of 85% below.
Check the starting
state at the regular
voltage above.
Replace the PTC.
- 15 -
YES
2
4
3
3
4
4
YES
5
NO
Replace OLP.
Normal.
YES
Normal.
NO
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc-w14 seriesGc-w101 seriesGc-w141 series

Table of Contents