Mitsubishi Electric PAR-SL94B-E User Instructions page 6

Wireless remote controller kit for ceiling suspended m

Advertisement

Wireless Remote Controller Kit
Other function selections
Now that you know how to change LOSSANY connectivity setting, there are several other settings that can be changed as well.
The following table lists the various settings that can be changed through the remote controller and the default settings.
Table 3.
Function
Power failure automatic recovery
Indoor temperature detecting
LOSSNAY connectivity
Auto mode (only for PUHZ)
Filter sign
Fan speed
Up/down vane setting
*1 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
Things to remember when entering function selections:
The basic procedure for entering function selections is the same as described for switching between LOSSNAY connectivity.
However, there are some differences at step
and step
for selecting the setting number.
The following Tables 4 and 5 list the various function settings, mode numbers and setting numbers.
Table 4 details the function of the entire refrigerant system while Table 5 shows the function that can be set for
the indoor unit.
Table 4. Itemized functions of the entire refrigerant system (select unit number 00)
Mode
Power failure
Not available
automatic recovery
Available (Approximately 4-minutes wait-period after power
is restored.)
Indoor temperature
Indoor unit operating average
detecting
Set by indoor unit's remote controller
Remote controller's internal sensor
LOSSNAY
Not supported
connectivity
Supported (indoor unit is not equipped with outdoor-air intake)
Not supported (indoor unit is not equipped with outdoor-air intake)
Auto mode
Energy saving cycle automitically enabled
(only for PUHZ)
Energy saving cycle automitically disabled
Table 5. Itemized functions of the indoor unit (select unit numbers 01 to 04 or 07)
Mode
Filter sign
100Hr
2500Hr
No filter sign indicator
Fan speed
Quiet
standard
High ceiling
Up/down vane
No vanes
setting
Equipped with vaneas (No.1 set)
Equipped with vaneas (No.2 set)
Setting the unit numbers
Set "00" as the unit number when setting function from Table 4.
When setting function from Table 5.
- When setting function for an indoor unit in an independent system, set the unit number to 01.
- When setting function for a simultaneous-Twin Triple quadruple indoor unit system, assign unit numbers from 01 to 04 to
each indoor unit.
- When setting the same functions for an entire simultaneous Twin Triple quadruple-indoor unit system, assign "07" as
the unit number.
Selecting the mode number
Select from Table 4 and Table 5.
Selecting the setting number.
E-134
for Ceiling Suspended models
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Not supported
Supported (indoor unit is not equipped with outdoor-air intake)
Not supported (indoor unit is not equipped with outdoor-air intake)
Energy saving cycle automitically enabled
Energy saving cycle automitically disabled
100Hr
2500Hr
No filter sign indicator
Quiet
Standard
High ceiling
No vanes
Equipped with vanes (No.1 set)
Equipped with vanes (No.2 set)
for selecting the unit number, step
Settings
Mode no.
Settings
Mode no.
PAR-SL94B-E
PCA-RP·KA
*1
*1
for selecting the mode number
Remarks
Setting no. Check
1
Approximately 4-minutes wait-
01
2
period after power is restored.
1
2
02
3
1
2
03
3
1
05
2
Setting no. Check
Remarks
1
2
07
3
1
2
08
3
1
2
11
3