1.4.2 Additional Recommended Equipment

• Standard, grounded 100-240 VAC 50/60 Hz connection
• Standard 19-inch 1U height equipment rack
• Depending on the power supply, an AC or DC Uninterruptible Power Supply (UPS) is recommended
NOTE

1.5 Cautionary Statements

CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
NX-7510 and NX-7530 integrated services platforms are initially configured with a
single AC power supply. An NX-7520 integrated services platform is initially configured
with two DC power supplies. Depending on the power supply, installation of an AC or
DC Uninterruptible Power Supply (UPS) is recommended if a second power supply is
installed in an NX-7510 or NX-7530.
There are no user-serviceable components inside the NX-7500 series integrated
services platform. Opening the chassis will void the warranty.
BIOS settings on the NX-7500 series integrated services platform should not be
changed. Changing any settings in the BIOS will void all warranty on the integrated
services platform.
To prevent the integrated services platform from overheating, never install in an
enclosed area not properly ventilated or cooled. For proper airflow, keep the front
and back sides of the integrated services platform clear of obstructions and away
from the exhaust of other equipment.
The recommended operating temperature is 32ºF to 104ºF/0ºC to 40ºC. Installation
in a closed or multi-rack assembly may raise the immediate ambient temperature
above the average room temperature. Exercise due caution.
Ensure the electrical circuit through which the integrated services platform is
powered can safely accommodate a 300 Watt power supply.
Motorola Solutions highly recommends you connect the NX-7500 series integrated
services platform to an Uninterruptible Power Supply (UPS). There are instances in
which the system software could become corrupt and un-recoverable in the event of
power loss, for example, during a system upgrade, database backup or database
restore operation.