EMP-1825/EMP-1815/EMP-1810
3.2 Basic Information on Troubleshooting
This section describes basic information needed when executing the troubleshooting.
3.2.1 LED Indicators
The control panel has three LEDs that indicate the operating status of the projector.
The following tables show what the indicators mean and how to remedy any problem
indicated.
Power indicator lights red: Abnormal
Indicator Status
Red
Red
Red
Internal Error
SEIKO EPSON
Figure 3-1 LED Indicators
Table 3-2. LED Indicator Status (Error)
Projector
Status
[Status]
Abnormality is detected from any of the following elements on
the MA board.
• ROM Error
• RAM Error
• I2C Error
• DR Status Error
• Sub System ROM Error
• Sub System Communication Error
[Remedy]
Disconnect the AC cable once, and reconnect it, then turn the
power on. If the same error occurs, replace the Optical Engine
and MAB set because the MA board is broken. (refer to
"Removing the Optical Engine and MAB (1) (MA Board
Assy.)" (p. 20)
(2) (Optical Engine)" (p.
Problem and Remedy
/
4.4.3 "Removing the Optical Engine and MAB
42))
3-3
CONFIDENTIAL
Power indicator
Lamp indicator
Temp indicator
ON
Blink
4.4.1
Revision:C
OFF