Emergency

Notification: Mark up to be notified the emergency agent about
the unit's operating information according to your notification
settings.
Host Name/Port: Enter the Host Name and port number of the
emergency agent program. The factory default port for this
function is 9002. However in some cases it is better to change
this port number for added flexibility or security. You can edit
this port between 1025 and 65535.
You can set up to 9 Host Name and port numbers.
SNMP
The Simple Network Management Protocol (SNMP) is an application
protocol to exchange the management information of network
devices.
SNMP Version: Selects a SNMP version if SNMP is allowed to
access to this device.
Port: Enter the number for SNMP port.
Community String (V2 only): Specifies the SNMP management
community in which you want to enable this system (e.g.
lgecommunity or public).
User (V3 only): Enter the security name for the SNMP.
Authentication (V3 only): Select a mode for the SNMP
Authentication. (MD5 or SHA)
Password (V3 only): Enter the password for the SNMP
Authentication.
Privacy (V3 only): Select a privacy mode for the SNMP
Authentication. (DES or AES)
Password (V3 only): Enter the password for the privacy mode.
Trap IP Address: Specifies the IP address of the computer you
intend to use as your network management station and to
which SNMP traps will be sent.
Trap Community String: Specifies the SNMP trap community in
which you want to enable this system (e.g. lgecommunity or
public).
Output
Relay Off
-
ALARM ACKNOWLEDGE: Use the ALM.OFF button to stop
alarm.
-
POST-ALARM TIME: The alarm is stopped after post-alarm
time.
System Alarm Out: Outputs the alarm (relay) signal via the
selected alarm out terminal number when the system has some
problem. If you do not use this function, select [NONE] option.
HDD Fail Alarm Out: Outputs the alarm (relay) signal via the
selected alarm out terminal number when the HDD is failed. If
you do not use this function, select [NONE] option.
Buzzer
Marks up when you want to activate the selected option.
Sensor: Makes a sound when a sensor occurs.
Motion : Makes a sound when a motion is detected.
System: Makes a sound when a cooling fan is not activated or
the HDD has bad sector.
NOTE
Data cannot be saved in HDD which is occurred bad sector.
But if HDD is installed more than 2 on this unit, data is saved in
other normal HDD.
When HDD has bad hold, can not operate normally. Replace
the HDD immediately .