Normal Audio System Adjustment; Ace Head Adjustment; E-E Output Level Check - Sony SLV-E580EE Service Manual

Hide thumbs Also See for SLV-E580EE:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
3. Overall Level Characteristic and Distortion Factor
Check
Purpose:
Check the record level, play level, and distortion factor against the
reference input.
Mode
Signal
Measurement point
Measurement equipment
Specified value
Confirmation Method:
1) Supply an audio signal of 400 Hz, –6.3 dBs simultaneously to
both L and R channels of Audio Line Input.
2) Make recording
3) Play back a recorded portion.
4) Confirm that a playback level is –6.3 dBs.
5) Confirm that a distortion factor is within 1%.
4. Overall S/N Check
Purpose:
Confirm that the S/N is within the specification.
Mode
Signal
Measurement point
TE
L 13942296513
Measurement equipment
Specified value
Confirmation Method:
1) Connect both L and R channels of audio line input to the GND.
2) Start recording.
3) Play the recorded part to confirm that the noise is below –67.5
dBs.
www
.
http://www.xiaoyu163.com
REC and PB (SP mode)
400 Hz, –6.3 dBs
Audio output terminal
Audio level meter and
distortion factor meter
Playback level: –6.3 ± 2 dBs
Distortion factor: 1% or less
REC and PB (SP mode)
No signal
Audio output terminal
Audio level meter
–67.5 dBs or less
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
2-5-2.

Normal Audio System Adjustment

• Make adjustment in the SP mode, unless otherwise specified.
Use a normal VHS cassette for an adjustment tape.
• Set AUDIO MONITOR to normal.
[Adjustment Sequence]

1. ACE Head Adjustment

2. E-E Output Level Check

3. Frequency Responce Check
4. Overall Level Characteristic and Distortion Factor
Check
5. Overall S/N Check
1. ACE Head Adjustment
Refer to the service manual of VHS MECHANICAL
ADJUSTMENT IV.
2. E-E Output Level Check
Purpose:
Confirm that the output level against the reference input is within
the specification.
Mode
Signal
Measurement point
Measurement equipment
Specified value
Confirmation Method:
Q Q
1) Simultaneously input a signal of 400 Hz, –6.3 dBs to both L
3
6 7
1 3
1 5
and R channels of Audio Line Input.
2) Confirm that the audio output level is –6.3 ± 2 dBs.
3. Frequency Responce Check
Purpose:
Confirm that the frequency characteristic is within the specifica-
tion.
Mode
Signal
Measurement point
Measurement equipment
Specified value
Tape path adjustment must have been completed.
Confirmation Method:
1) Supply a signal of 400 Hz, –26.3 dBs to both L and R chan-
nels of Audio Line Input.
2) Connect the audio level meter to the Audio Line Output.
3) Adjust the attenuator so that the audio level meter will indi-
cate –26.3 dBs.
4) Make recording in the SP mode.
5) Set an audio line input signal to 7 kHz and make recording.
6) Playback a recorded portion, and measure output levels at 400
Hz and 7 kHz.
7) Confirm that the 7 kHz playback output level within a range
co
of the 400 Hz playback output level 0 ± 3 dB.
.
7-6
9 4
2 8
E-E
L, R: 400 Hz, –6.3 dBs
Audio output terminal
Audio level meter
–6.3 ± 2 dBs
0 5
8
2 9
9 4
2 8
REC and PB (SP mode)
400 Hz, –26.3 dBs
7 kHz, –26.3 dBs
Audio output terminal
Audio level meter
0 ± 3 dB
m
9 9
9 9