The Specification Of Power - Pioneer LISAS-B-1403 Service Manual

Dc inverter split heat pumps
Table of Contents

Advertisement

The Specification of Power

8. The Specification of Power
Indoor/Outdoor
Connecting Wiring
Model
Phase
Power
Frequency and Voltage
Circuit Breaker/ Fuse (A)
Indoor Unit Power Wiring (mm
Ground Wiring
Outdoor Unit Power Wiring
Indoor/Outdoor
Connecting Wiring
Line Voltage Electric Signal
Low Voltage Electric Signal
20
Model
Phase
Power
Frequency and Voltage
Circuit Breaker/ Fuse (A)
Indoor Unit Power Wiring (mm
Ground Wiring
Outdoor Unit Power Wiring
Line Voltage Electric Signal
Low Voltage Electric Signal
CB024GMFI24MLD
208-230V, 60Hz
2
)
4.0 (AWG12)
3×4.0 (AWG12)
3×1.5(AWG16)
3×0.5 (AWG24)
CB012GMFI16MLD
CB018GMFI16MLD
1-phase
208-230V, 60Hz
20/16
2
)
2.0 (AWG14)
3×2.0 (AWG14)
4×1.5 (AWG16)
CB036GMFI16MLD
1-phase
1-phase
208-230V, 60Hz
40/30
60/40
4.0 (AWG12)
3×4.0 (AWG12)
3×1.5(AWG16)
3×0.5 (AWG24)
CB048GMFI16MLD
1-phase
208-230V, 60Hz
70/55
4.0 (AWG12)
3×4.0 (AWG12)
3×1.5(AWG16)
3×0.5 (AWG24)