Bosch Crystalline Solar Modules Installation And Operation Manual page 8

Crystalline solar modules
Table of Contents

Advertisement

8 | Installation guidelines
When fastening modules with slide-in or lay-in systems,
the following should be observed:
 Bearing area on frame: The frame must be covered on
the upper side by at least 5 mm and no more than
12 mm.
 The slide-in or lay-in system must overlap the under-
side by at least 3 mm and have a surface area of at
least 2 mm width.
When fastening modules in the area of the module or
drainage corners, the following should be observed:
 If corner clamps are used, a minimum cover area of
28 mm of the clamp must be ensured (length of the
assembly clamp).
 The assembly clamp must overlie by min. 8 mm and
max. 12 mm on the frame (depth of assembly clamp).
Bosch Solar Module c-Si M 60 EU I Bosch Solar Module c-Si M 60 S EU I Bosch Solar Module c-Si P 60 EU I Bosch Solar Module c-Si M 48 EU I Bosch Solar Module c-Si M 48 S EU
Module manufacturer code 14, 17, 23
990 ± 2
15
4 x Mounting holes for grounding cable
figure 2: reverse side c-Si M 60 and M 60 S, P 60, manufacturers
14, 17 and 23
15
4 x Module mounting holes
figure 3: reverse side c-Si M 48, c-Si M 48 S, manufacturer 23
20
990 ± 2
Bosch Solar Energy AG
au