Installation Checldist - Kenmore 153 Owner's Manual

Power miser 9 series 30/40 gal. short 30/40/50/66/80 gal.
Hide thumbs Also See for 153:
Table of Contents

Advertisement

Installation
Instructions
installation
Checklist
(cont'd)
• Whether or not the element conversion is made, the model
rating plate must be marked. Using a hard point ink _en,
check the appropriate block within the model rating p_ate,
which is located adjacent to the lower access panel.
Is the fuse or circuit breaker size correct as shown in the chart
in the "Product Specifications" section?
• Are the wires from the circuit breaker or fuse service to the
water heater's junction box on the correct wire size (gauge) as
shown in the chart in the "Product Specifications" section?
o Is the new temperature-pressure
relief valve properly
installed, andpiped to an adequate drain? See Temperature-
Pressure Relief Valve section
_g
Is the water heater completely filled with water. See Filling
the Water
Heater"
instructions
in the "Installation
Instructions" section,
Will a water leak damage anything? See "Facts to Consider
About the Location" secuon.
Are the cold and hot water lines connected to the water heater
correctly? See "Water Piping" instructions in the "Installation
Instructions
section
Is there adequate clearance for maintenance around the water
heater?
Do you need to call your electric company to check your
wiring?
HOT
CONDUIT
COLD
TEMPERATURE-
RELIEF VALVE
(Do not cap or plug)
6
AIR GAP
FLOOR
DRAIN
MODEL RATING
PLATE
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents