Leakage Checkpoints - Kenmore 153 Owner's Manual

Kenmore water heater user manual
Hide thumbs Also See for 153:
Table of Contents

Advertisement

Operational
Conditions
(Continued)
Leakage Checkpoints
FIGURE 27.
Read and understand instruction
manual and safety
messages
before installing,
operating
or
servicing this water heater.
Failure to follow instructions
and
safety
messages
could result in
death or serious
injury.
Instruction Manual must remain
with water heater.
Read this manual
first. Then before
checking
the water
heater
make
sure the gas supply
has been
turned
"OFF",
and never
turn the gas "ON" before
the tank is completely
full of water.
Never
use this water
heater
unless
it is completely
filled
with
water.
To prevent
damage
to the tank, the tank must be filled
with water.
Water
must flow
from the hot water
faucet
before
turning
"ON" gas to the water
heater,
see Figure
27.
A. Water at the draft hood is water
vapor which
has condensed
out of the combustion
products.
This is caused
by a problem
in the vent.
Contact
the gas utility.
B. *Condensation
may be seen
on pipes
in humid
weather
or
pipe connections
may be leaking.
C. *The anode
rod fitting
may be leaking.
D. Small
amounts
of water
from
temperature-pressure
relief
valve may be due to thermal
expansion
or high water pressure
in your area.
E. *The temperature-pressure
relief valve may be leaking at the
tank fitting.
F. Water from a drain valve may be due to the valve being slightly
opened.
G. *The drain
valve
may be leaking
at the tank fitting.
a.
Combustion
products
contain
water
vapor
which
can
condense
on the cooler
surfaces
of the tank.
Droplets
form
and drip onto the burner
or run on the floor. This is common
at the time of start-up
after installation
and when
incoming
water
is cold.
Water
in the water
heater bottom
or on the floor may be from
condensation,
loose
connections,
or the
relief
valve.
DO NOT replace
the water
heater
until a full inspection
of all
possible
water
sources
is made
and necessary
corrective
steps taken.
Leakage
from other appliances,
water
lines, or ground
seepage
should
also be checked.
To check
where
threaded
portion
enters
tank, insert
cotton
swab
between
jacket
opening
and fitting.
If cotton
is wet,
follow
"Draining"
instructions
in the Periodic
Maintenance
section
and then
remove
fitting.
Put pipe
dope
or teflon
tape
on the threads
and replace.
Then
follow
Filling
the
Water
Heater
instructions
in the Installing
the New
Water
Heater
section.
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

334530Hydrosense 153.334430Hydrosense 153,334530

Table of Contents