Page 1
CMD-J6/J26 SERVICE MANUAL E Model ______________________________________________________________________________________________________________ SPECIFICATIONS Signalling format Dual-Band Frequency range E-GSM 900 MHz, Transmit: 880 ~ 915 MHz Receive: 925 ~ 960 MHz DCS 1800 MHz, Transmit: 1710 ~ 1785 MHz Receive: 1805 ~ 1880 MHz GSM power class Class 4 (2W) DCS power class Class 1 (1W)
Page 2
Power requirements 3.7 V (nominal) Operating temperature -10°C to +55°C Accessories operating temperature ± 0°C to +45°C Connectors External RF connector Bottom Connector (12-pin flat I/O connector) Mini plug head set jack WAP (CMD-J6 only) Supported protocols by the WAP v.1.1 compliant browser: Wireless Session Protocol (WSP) Wireless Caching Model Wireless Transaction Protocol (WTP)
TABLE OF CONTENTS SECTION 1 Specifications (see Cover sheet) SECTION 2 General Descriptions 2.1 Multi Band . 04 2.2 Radio Frequency Power Level .. 05 2.3 Speech Codec . 05 2.4 Languages . 05 2.5 Battery Charging .. 06 2.6 Battery Safety ...
SECTION 2 GENERAL DESCRIPTIONS 2.1 Multi-band : CMD-J6/J26 support E-GSM 900 and DCS 1800 multi-band functionality. For the use in Europe and in other countries worldwide, ETSI has specified GSM standards into two frequency bands. That is the 900-MHz and 1800-MHz band and is usually referred to as GSM900 and GSM1800 (formerly DCS1800).
2.2 Radio Frequency Power Levels: Between the DCS 1800 and both GSM Systems are differences regarding the power level. DCS 1800 basically needs lower power levels. If the performance of a MS for GSM system was certified of 2W (Power Class 4), then in the DCS-1800 system it is only 1W (Power Class 1).
2.5 Battery Charging There is no charging circuitry in the battery pack. The CMD-J6/J26 has complete charger function internally. The telephone can be charged only with the battery connected the phone. This situation can be sub-divided into two situations: the phone is on or off. It can be charged with the AC Adapter, Travel Charger or Cigar Lighter Charger.
SECTION 3 OPERATING INSTRUCTIONS 3.1 The Basic Features of the CMD-J6/J26 • Parts and Controls This section provides a brief guide to the operation and facilities available on the CMD-J6/J26. Refer to the Operating Manual for full operational information. Antenna External connector Display (Charging and Accessories)
• The Centre Key # Press the Centre Key in standby mode to access the WAP mode if WAP settings are configured. (CMD-J6 only) # During a call, press the Centre Key to access the Call Menu. # In Sub-menus, access/exit the help function by pressing the Centre Key •...
SECTION 4 DISASSEMBLY IMPORTANT NOTE : The IMEI number is the electronic identification of the hardware, which is stored electronically. There should be no discrepancy between the number on the sticker and the number within the set memory allowed. In case of replacing the lower cabinet it is to make sure that the IMEI Sticker mounted on the lower case (visible from the battery compartment) will be replaced to the new housing part as well.
Page 12
IMPORTANT: Do not detach the shield case from the main board CABINET LOWER Re-assembly procedure : To re-assemble the unit, apply the reverse order of the above mention disassembly procedure.
4.2 Interface to GSM-Tester Test Set Up for CMD-J6/J26 Level 1 Testing CMD- J 6/J 26 Battery Pack Test SIM Card Service Test Connector RF output : SMA jack STC-03 Part No. 3-224-391-01 RF input Connector GSM TESTER This unit acts as a base station providing necessary signalling requirements and provides GSM signal...
Level Test Procedure with GSM TESTER recommendation: • Simulate GSM call processing to check the functionality of transmitting and receiving audio signals of loudspeaker and microphone. • Basic GSM transmission & reception parameter testing to ensure that handsets performance compiles with standard GSM specification.
Section 5 PROGRAMMING INSTRUCTIONS 5.1 Requirement • PC (486 type or higher) with Microsoft Windows Operating System • One COM-port free for usage • The Data Transfer Cable (p/n 1-757-348-11) PREPARATION FOR SOFTWARE UPDATE DATA TRANSFER CABLE 5.2 Hardware set-up •...
• Select file/Settings and check if the settings for the Com Portand Speed are correct. − The FlashLoader automatically detects all available Com ports on the PC. (COM 1 or COM 2) − Baud rates up to 812500bps will be supported, but standard PCs, unless it is correctly customised (i.e.
IC 2 IC 2 is the platform of the A/D-D/A converter for the interfacing and processing of baseband I/Q signals and voice signals. It includes: ! the complete set of baseband functions to perform the interface and processing of voice signals, ! interface for processing of baseband components as In Phase (I) and Quadrature (Q) signals which support single slot and multi slot mode, ! associated auxiliary RF control features,...