PT Display—PT Last Display Duration in Idle Mode
Specifies the length of time that the current information remains on the display after the extension returns to
idle status.
Default
5 s
Value Range
1–15 s
Maintenance Console Location
4.5 [2-3] Timers & Counters
Programming Manual References
None
Feature Manual References
None
Air Synchronization—Watching Degeneracy
Specifies the length of time that a Slave CS can maintain an ongoing call after air synchronization is lost.
Default
300
Value Range
60 ´ n (n=0–300) s
Maintenance Console Location
4.5 [2-3] Timers & Counters
Programming Manual References
13.6 [11-5] Air Synchronization
Feature Manual References
None
Voice Mail (Caller from VM to CO)—On-hook Wait Time
Specifies the length of time from when the VPS seizes a CO line (for example, to transfer a call) until the VPS
goes on hook. If the time specified here is too short, the VPS will be unable to dial the number and make a
connection.
Default
10 s
Document Version 2011-10
4.5 [2-3] Timers & Counters