TECHNICAL MANUAL
ALM
ALM
NO.
CODE
34
MJD03
35
MJD04
36
MJD05
37
MJD06
38
MJD07
39
MJD08
40
MJD09
41
MJD10
42
MJD11
43
MJD12
MMC: 852
ALARM
Red Alarm
Red Alarm Rec
Yellow Alarm
Yellow Alarm Rec
Blue Alarm
Blue Alarm Rec
Bit Error Alarm
NTWRK Event
SPID Init Err
SPID Init Rec
Home Page
PROGRAMMING
PART 2 JUNE 2006
DEFINITION
Locally detected loss of PCM carrier on
T1/PRI card for more than 250 ms.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
PCM carrier detected locally on T1/PRI
cards.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
Remotely detected failure transmitted in
frame on T1/PRI card.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
Remotely detected failure restored
transmitted on T1/PRI card.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
All one's being transmitted on facility on
T1/PRI card.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
A blue alarm condition has been
cleared.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
Alarm is activated when the when error
-6
rate exceeds 1x10
errors. Note: 1x10
is threshold for minor alarm, 1 x 10
threshold for major alarm errors on
T1,PRI or BRI..
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
An Implausible event has occurred on
the PRI or BRI Network digital line.
Protocols do not match or subscriber ID
mismatch.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
The BRI received an error from the
network
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10),Channel(1 through 16)
The BRI has recovered from an error on
the network
Alarm Data = Cabinet, Slot Channel
C1,2
(S1 through 10),C (1 through 16)