Remote Access; Remote Pc - Bosch AMAX 2100 Installation Manual

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

AMAX 2100 / 3000 / 4000
When the report is transmitted with Conettix IP Communication, some reports might be
missed. It is recommended not to separately use the ITS-DX4020-G module. If the ITS-DX4020-
G module is used, other network modules (e.g. B426) or the public telephone network can be
set as backup channel to ensure that no reports are missed.
The communication path of B426 / ITS-DX4020-G is as follows:
Module
Module 1: B426 module 1 / ITS-
DX4020-G
Module 2: B426 module 2
Only when IP module 1 is used and set to paths 1 to 4, the report can be sent to those paths.
7.1.5

Remote Access

The AMAX panel supports remote programming via USB, telephone, or IP network using the
software A-Link Plus. The following option can be performed:
Remote Access Armed
Remote programming
7.1.6

Remote PC

IP Address
RPC IP address is a fixed IP address for remote programming software.
Port Number
RPC port number is the port number for remote programming.
DHCP Update / RPC poll Time Interval
DHCP update / RPC poll time is the interval at which AMAX panel connects to the RPC
(Remote Programming PC).
The AMAX panel send UDP data packets to the RPC according to the DHCP Update Time
Interval setting (0=disabled 1-15h Interval), when the panel is reset and when call back is
finished.
RPC gets the Subscriber ID, IP address and port from the UDP data packets (IP No. and Port
is parsed from UDP data packet).
RPC with running RPS (Remote Programming Software = A-Link Plus) saves the received UDP
data packet information into its own RAM, the information is lost after RPS is closed.
Bosch Sicherheitsysteme GmbH
Setting the date and time
Uploading / downloading programming parameters
Remote arming / disarming of each area
Enabling / disabling the alarm siren of each area
Enabling / disabling each output
This option enables / disables the remote access for the function alarm.
This option enables / disables the remote access for programming. If this function is
disabled, the system can not be programmed via an IP network anymore.
Address Setting
134
250
Installation Guide
Settings | en
Corresponding
Communication Path
Paths 1 and 2
Paths 3 and 4
2014.11 | 02 | F.01U.267.112