Pump Sizing; Pressure Drop Curves - Bosch C 1210 ES Applications Manual

Bosch therm tankless water heaters
Table of Contents

Advertisement

THERM Tankless Water Heater Applications Manual

5 Pump sizing

The following section outlines sizing pumps for domestic hot water
circulation and tank loading. Only models approved for such
applications are listed in this section.
Pump must be bronze or stainless steel.
Size the pump according to the system pressure drop chart
below.
Maximum flow allowed through the recirc loop is 5 GPM.
If the water heater is used within an approved hot water
recirculation application and supplied with circulated
water, the heat exchanger warranty is decreased. Please
refer to the installation manual for detailed warranty
period information.
Run the system for 30 minutes to remove debris from the
plumbing. Then remove the unit's inlet water fi lter to
decrease pressure drop through the system.
If the inlet water fi lter, when removed, contains debris
install a Y-strainer (installer supplied) on the cold water
inlet.

5.1 Pressure drop curves

660 EF/EFO
70
60
50
40
30
20
10
0
0
0 .
1
0 .
BOSCH THERMOTECHNOLOGY CORPORATION
C 800 ES,
C 920 series,
C 1050 ES
C 1210 series
2
0 .
3
0 .
Flow (GPM)
2400 ES,
830 ES,
2700 ES,
940ES/ESO
GWH 715 ES,
4
0 .
Data subject to change without notice | 01.2011
| 7
5
0 .