960H Day/Night IR Bullet Camera
6
Installation
6.2 Monitor connection
Terminal block
Screw
Terminal
10.16
(0.4)
2.6x3.2
(0.1x0.12)
6.3 Camera adjustment
CAUTION!
To prevent humidity problems, the camera must be installed in dry conditions.
The housing front should never be removed in wet or moist conditions. Doing
so could cause condensation on the inside of the camera window.
1.
Remove the housing front.
2.
Connect service monitor. (optional)
3.
Adjust zoom and focus.
4.
Fasten the zoom and focus lever.
5.
Adjust OSD settings. (refer to OSD section)
6.
Disconnect service monitor cable. (optional)
7.
Re-mount housing front. Include warning to (1) check rubber seal is in place. And (2) tighten
housing front firmly to ensure protection against water ingress.
V
Housing front fastened enough.
(No gap between housing front and housing body)
Protection against water ingress ensured.
Bosch Security Systems
Terminal block connector
18.2(0.71)
5.08(0.2)
Camera
"+","-" Indication
mm
(in.)
X
Housing front not fastened enough.
(Gap between housing front and housing body)
Risk of water ingress.
User Manual
Installation | en
Female
BNC connector
Ground contact
Signal contact
TV Monitor
Video In
*Sold separately
2012.11
9