Siemens Building Technologies
Fire Safety & Security Products
Fig. 14
Bridge mode A layout
A
Camera Connections
B
VIS3I-328 Monitor Node
C
Monitor Connections
D
VIS3I Bridge Unit
The system configuration for the bridge node will need to encompass the total
number of cameras, monitors and VCR/MPX on all the 'monitor nodes'. The
camera text needs to be configured at each monitor node. Keyboard access to
monitors, user access to camera view/control and monitor access must be
configured at the bridge node.
An input trunk must be configured at the bridge node for each remote monitor to be
controlled. Each input trunk must have a camera number specified even though
nothing is physically connected to the bridge camera inputs. Alarms for the chosen
trunk inputs must have their type set to either trunk or none.
Tab. 33 shows example configuration changes for bridge mode A controlling four
expanded VIS3I-328 remote nodes.
Screen
Parameter
System
Nodes
Node Trunks
Cameras
Monitors
Alarm
Alarms on keyboards & PCCON:
1 - 64
Type
Node Trunk
Neighbour Node End: Node
1 to 16
Neighbour Node End: Trunk
Local Node End: Direction
Local Node End: Camera
Node Trunk
Neighbour Node End: Node
17 to 32
Neighbour Node End: Trunk
Local Node End: Direction
Local Node End: Camera
Node Trunk
Neighbour Node End: Node
33 to 48
Neighbour Node End: Trunk
Local Node End: Direction
Local Node End: Camera
Node Trunk
Neighbour Node End: Node
49 to 64
Neighbour Node End: Trunk
Local Node End: Direction
Local Node End: Camera
Comm.
Function
Channel
Protocol
1 - 4
Bridge mode A configuration settings
Tab. 33
Value
5 (Bridge node is always node 5)
4 (1 per Monitor node)
256 (Total of cameras on all nodes)
64 (Total of monitors on all nodes)
Trunk or None (required to permit trunk
inputs below)
1
1 to 16
Input
1 to 16
2
17 to 32
Input
17 to 32
3
33 to 48
Input
33 to 48
4
49 to 64
Input
49 to 64
Network control input
PCCON2/3 remote control