CONSTRUCT CEILING SUPPORT

Plan the Location of the Hood and Ductwork
The ceiling structure must be capable of supporting the
weight of the insert sleeve (approximately 100 pounds)
and any inadvertent user contact loads.
• Use a plumb bob to check the location. The
countertop/cooktop below the insert sleeve must be
centered with the insert sleeve.
• The insert sleeve should extend beyond the front and
rear edge of the cooking appliance.
Front
Align with
center of
cooktop
Front view
Island Installation Preparation
(for Island Installation)
Ceiling
Hood
ducting
centerline
30" Min.
36" Max.
installation
height
Cooktop
Countertop
• The insert sleeve in the ceiling must be centered left
to right over the cooktop.
30" Min.
36" Max.
installation
height
13
Side view