3.Applicable Models
EMP-600/800/810/811/820,30/52,720/730/520,73/53/74/54,735,8300/9300,7800/7850,S1/S1H,61/81,830/835,740/745/732/
737,821/828,7900/7950,S3/S4,765/760,755/750,62/82/X3,1715/1710/1705/1700,6000/6100,1815/1810,S5/X5/83/822,260/280/
6110/6010,400W/410W,83+/822+, 1825, EX90, G5350/G5300/G5150/G5100/G5200W/G5000, S6/X6/W6, 1735W/1730W/1725/
1720,
Z8000WU/Z8050W

4.Projector state and commands

4.1.Standby state (operation indicator is in orange)
When a projector is in a standby state, executable commands depend on projector models and standby configuration (network on, network
off). Refer to the following table.
Models
61/81
830/835
740/745/732/737
821/828
S3/S4
765/760/755/750
62/82/X3(76)
6100/6000
1715/1710/1705/1700
1815/1810/1825
S5/X5/83/822/83+/822+/EX90
260/280
6110/6010
400W/410W
G 5 3 5 0 / G 5 3 0 0 / G 5 1 5 0 / G 5 1 0 0 /
G5200W/G5000
S6/X6/W6
1735W/1730W1725/1720
84/85/824/825/826W
Z8000WU/Z8050W
7800/7850/
8300/9300
7900/7950
(note3)
Others
(note1) EMP-61/81/830/835/740/745/821/828 returns "ERR" when it received commands other than PWR ON, PWR? , LAMP? and NULL
commands.
(note2) EMP-7800/7850 returns "ERR" when it received commands other than PWR ON, PWR? , SOURCE? and NULL commands.
(note3) EMP-8300/9300 returns "ERR" when it received commands other than PWR ON, SOURCE xx, PWR? , SOURCE? And NULL
commands.
All projectors returns "ERR" when the command format is not good.
All projectors returns "ERR" when the projector is not ready to reply the command.
Null command is command name for "ENTER" or "RETURN" key of the keyboard
The reply is ":"
ESC/VP21 Command User's Guide for Business Projectors
network on/off
network on
network off
-
Model s
78007850
7900/7950
8300/9300
8300+ELPXP01
830/835
740/745
732/737
760/765
750/755
61/81,821/828
Configuration
PWR ON , PWR? , LAMP?
PWR ON , PWR? , SOURCE? , Null
command (note1)
PWR ON (note2)
Power Consumption
Network off
about 1.5W
about 1.5W
about 1.5W
about 1.0W
about 4.0W
about 5.0W
5 of 28
Executable Commands
Network on
about 47W
about 60W
about 60W
about 38W
about 35W
(only 745/737/765/755)
about 35W