  • Page 1 High Resolution WDR V/F Dome Camera SID-562 User Guide Before installing and operating this product, please read this manual thoroughly. ENGLISH...
  • Page 2 Before operating the camera, confirm the camera model and proper input power voltage. In order to that you can understand this manual thoroughly, we'll introduce our model description. n SID-562 SERIES • NTSC MODEL • PAL MODEL SID-562(W)N SID-562(W)P n MODEL DESCRIPTION The lightning flash with an arrowhead symbol, within an equilateral triangle is • SID-562(W)X...
  • Page 3: Table Of Contents

    Contents Features Contents • Precautions …………………………………………………………………… 7 SSNR (Samsung Super Noise Ultra High Resolution Reduction) Function Components and Accessories • …………………………………………… 9 By adopting a double-speed 410,000 pixel(NTSC), The high performance SV-IV DSP chip dramatically • Overview ………………………………………………………………………… 9 470,000(PAL) pixel Sony CCD, the camera produces reduces the gain noise in digital image processing, clear picture quality with a horizontal resolution of producing clear, sharp images in low lighting •...
  • Page 4: Precautions

    Precautions Samsung Techwin cares for the environment at all product manufacturing stages to preserve the environment, and is taking a number of steps to provide customers with more environment-friendly products.The Eco mark represents Samsung Techwin’s will to create environment-friendly products, and indicates Do not install under extreme Do not install in high humidity that the product satisfies the EU RoHS Directive. temperature conditions. environment. Warnings & Cautions This information is provided to ensure your safety and to prevent any losses, financial or otherwise. Please read it carefully and use the product accordingly.
  • Page 5: Components And Accessories

    Precautions Components and Accessories ❶… Do not expose the camera to radioactivity. SID-562 Instruction Manual… M4 Tapping Screw 4EA ❶ M4 Machine Screw 4EA………………… Adapter plate … Installation Video Output Cable… If it is exposed to radioactivity, For heated CCD, it will be out of order.
  • Page 6: Installation

    Overview Installation ❶ Pan Base : control panning angle of camera Notes Rotate Base : control rotating angle of camera • T he installation should be done by qualified service personnel or sysytem installers. X3.6 Vari-focal Lens Module • I f the ceiling material is not strong enough to hold the installation screws, the Rotate Base Holding Screw : fix rotated position camera may fall off. Reinforce the ceiling as needed. Pan Base Holding Screws (Color : Silver) : fix panned position RS-485 Control Cable : The detailed description refers to p14 When installing on a adapter plate Power Input Jack...
  • Page 7: Adjust The Panning And Tilting, Rotating While Watching The Monitor

    Connection Installation Adjust the panning and tilting, rotating while watching the monitor Connecting to Monitor Connect the VIDEO-OUT jack to the VIDEO-IN jack of monitor. 73˚ 145˚ 195˚ 170˚ Tilt Base Monitor CCTV Camera Rotate Base Pan Base • As the connecting method varies with the instruments, refer to the manual supplied with the instrument.
  • Page 8: Rs-485 Communication Control

    ●CAMTITLE ●SYNC SPECIAL ●COMM ADJ ●PRIVACY ●DIS Using a RS-485 communication, it will be able to control the OSD menu at the SAMSUNG ●LANGUAGE ●RESET ●RETURN TECHWIN System Controller or DVR. EXIT (1) The case which it controls from the PC...
  • Page 9: Ssnr

    Operating Your Camera 1. Press the Function Setup switch. DC : Select Auto Iris Lens • Main setup menu is displayed on the monitor screen. • When DC is selected, you can control screen brightness. The range of brightness control is MAIN SETUP between 1 and 70.
  • Page 10 Operating Your Camera SENS-UP : ※ Select one of the following 5 modes, as appropriate for your purpose. When it is night or dark, the camera automatically detects the light level and ATW : Select this when the color temperature is between 1,800ºK and 10,500ºK. maintains a clear picture if this mode is activated.
  • Page 11 Operating Your Camera Operating Your Camera BLC : Enables a user to directly select a desired area from a Notes picture, and to view the area more clearly. • Select ‘BLC’ to adjust the area to be enhanced and • S ince the following symptoms may occur according to the ambient illumination when WDR is selected, set it to OFF.
  • Page 12: Image Adj

    Operating Your Camera DAY/NIGHT IMAGE ADJ. You can display pictures in color or black and white. 2. Select a desired mode using the Function 1. When the SETUP menu screen is displayed, 1. When the SETUP menu screen is displayed, select ‘DAY/NIGHT’ by using the select ‘IMAGE ADJ.’...
  • Page 13: Special

    Operating Your Camera Notes SPECIAL SPECIAL • W hen the CAM TITLE menu is ‘OFF’, no title 1. CAM TITLE 1. When the SETUP menu screen is displayed, select ’SPECIAL‘ by using the Function will be displayed on the monitor screen 2. SYNC Setup switch so that the arrow indicates ’SPECIAL‘. even if you enter one.
  • Page 14 Operating Your Camera - TRANSP : D etermine the transparency of selected area as Notes controlling number from 0 to 3. - RETURN : S elect this to save the PRIVACY menu • W hen using AC power at 60Hz(PAL : 50Hz) frequency, you can use the L/L type synchronization. settings and return to the SPECIAL menu. • W hen the power is DC 12V, the SYNC menu is fixed to the 'INT' mode. DIS (Digital Image Stabilizer) : This function mitigates any picture movement due to external factors such as wind. MOTION DET : You can monitor activity more efficiently, because a signal is generated by the camera whenever motion is detected.
  • Page 15: Troubleshooting

    485- Flip / Mirror On / Off Communication RS-485 (Baudrate 2400, 4800, 9600, 19200, 38400, 57600 bps Selectable) ▶ Check the RS-485 Communication establishment initial value Protocol Samsung Techwin protocol, Pelco-D protocol * RS-485 Communication establishment initial value ENVIRONMENTAL Item Camera ID BAUD RATE UART MODE RET PKT Operating Temperature / Humidity -10°C ~ +50°C / 20% ~ 80% RH...
  • Page 16: Dimension

    KYUNGNAM, KOREA, 641-716 European Representative Name 105.5mm European Representative Address Equipment Type/Environment CCTV Camera Model Name SID-562P/WP Beginning Serial NO. S8110001 Year of Manufacture 2008. 12. 01 Conformance to EN 50081-1 : 1992 EMC-Directive 89/336 EEC and 92/31/EEC EN 50130-4 : 1996 We, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s). Manufacturer SAMSUNG TECHWIN CO., LTD Legal Representative in Europe Signature Signature Full Name BONJENG GU Full Name Position QUALITY CONTROL MANAGER Position Place CHANGWON, KOREA Place 108mm Date 2008. 12. 01 Date COLOR DOME CAMERA User Guide...
  • Page 17 SAMSUNG TECHWIN EUROPE CO., LTD. • • 1480 Charles Willard St, Carson, CA 90746, UNITED STATES Samsung House, 1000 Hillswood Drive, Hillswood Business Tol Free : +1-877-213-1222 FAX : +1-310-632-2195 Park Chertsey, Surrey, UNITED KINGDOM KT16 OPS www.samsungcctvusa.com TEL : +44-1932-45-5300 FAX : +44-1932-45-5325 www.samsungtechwin.com...