HP 562A Operating Instructions Manual page 23

Table of Contents

Advertisement

J
Model
562A
PRINT
COMMAND
+
+
HOLDOFF
CLUTCH
BINARY
2MS
DELAY MV
GOUS
DELAY MV
RESET
- TRANSFER
+
TRANSFER
SCAN
-----------
01081-1
Section V
PRINT COMMAND
Changes state of PRINT COMMAND BINARY.
Minimum amplitude for
+
and - print commands
is 6 volts.
HOLDOFF VOLTAGE
Supplied to data source when PRINT COMMAND
BINAR.IES change state. The
+
holdoff is
15 volts in amplitude, - holdoff is 6 volts.
CLUTCH BINARY
State is changed by leading edge of holdoff voltage,
clutch solenoid becomes energized. Amplitude of
change is 35 volts.
2 MS DELAY MV
State is changed by leading edge of clutch bi.nary
signal. Amplitude of change is approximatnly
12 volts.
60 IJ.S DELAY MV
State is changed by trailing edge of 2 MS MY.
60 IJ.S delay is for data storage in storage bina-
ries.
15 volts amplitude, resets PRINT COM-
MAND BINARIES.
RESET
Initiated by leading edge of 60 IJ.S MV pulse.
Amplitude 12 volts, width 10
IJ.S.
+
and - TRANSFER PULSES
Initiated by trailing edge of 60 /lS MV.
- transfer
pulse is 5 volts,
+
is 3 volls, width 10
IJ.S.
SCAN
Initiated when shutter blocks light to photo con-
ductor. Amplitude 25 volts, width approximately
160
IJ.S.
Resets clutch binary.
Figure 5-1.
Timing Voltages