Dimensions: Horn - Siemens SITRANS LR 300 Instruction Manual

Iq radar 300
Hide thumbs Also See for SITRANS LR 300:
Table of Contents

Advertisement

Dimensions: Horn

Ø 80mm
(3")
horn
100mm
(4")
150 mm
(6")
200 mm
(8")
A purging system is an option available for this antenna type. This provides an inlet on
the flange where cooling air or cleaning fluid may be supplied. The air or liquid passes
through the flange and exits the inside of the horn to clean the antenna system.
Notes:
• Process temperature and pressure capabilities are dependent upon information on
the process device tag. Reference drawing listed on the tag is available upon
request.
• The Process Device Tag shall remain with the process pressure boundary assembly.
In the event the instrument package is replaced, the Process Device Tag shall be
transferred to the replacement unit.
WARNING: The user is responsible for the selection of bolting and
gasket materials which will fall within the limits of the flange and
its intended use and which are suitable for the service conditions.
7ML19985CL02
enclosure/
electronics
process
device tag
flange
131mm
(5. 1 6")
225.8mm
(8.89")
325.1mm
(12.8")
SITRANS LR 300 – INSTRUCTION MANUAL
Nominal
Horn
Horn
Horn
O.D.
Height
Size
100mm
95.3mm
131.0mm
(4")
(3.75")
(5.16")
150mm
146.0mm
225.8mm
(6")
(5.75")
(8.89")
200mm
199.4mm
325.1mm
(8")
(7.85")
(12.8")
Notes:
• Signal amplitude increases with
horn diameter, so use the largest
practical size.
• Optional waveguide extensions
and/or purging system * can be
installed between the flange and
the antenna.
Beam
Angle
28
degrees
20
degrees
12
degrees