Dip Switch Settings - Bosch LTC 8713 Series Instruction Manual

Alarm port expanders
Hide thumbs Also See for LTC 8713 Series:
Table of Contents

Advertisement

LTC 8713 Series | Instruction Manual | Installation
4.4

DIP Switch Settings

The LTC 8713 Series Alarm Port Expander
communicates with the Allegiant series main bay and
the LTC 8540/00 Alarm Interface Unit via RS-232
communications. The LTC 8713 Series Alarm Port
Expander contains internal DIP switches which can be
used to set the communication parameters. The cover
must be removed if the DIP switches need to be
changed from their factory default settings. See Cover
Removal. The following table summarizes the DIP
switch settings and their associated features. Note that
after changing any of the DIP switch settings, the AC
power must be turned off and on before the changes
can take effect.
Figure 2 Location of DIP Switches
Bosch Security Systems | 02 February 2004
4.4.1 DIP Switch Settings
S402 DIP Switch: These settings must match those on
the LTC 8540/00 Alarm Interface Unit.
Switch Number
1
2
3
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
On
Off
On
On
On
Off
On
On
On
4
Off
On
5
6
OFF
OFF
OFF
ON
ON
OFF
ON
ON
7
8
1
Note that the default baud rate for LTC 8540/00 units starting with
serial No. 1500 changed from 1200 to 19200.
S401 DIP Switch: These settings must match the
"ALARM" Port settings on the Allegiant series main bay.
Switch Number
1
2
3
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
On
Off
On
On
On
Off
On
On
On
4
Off
On
5
Off
On
6
7
8
1
Allegiant default baud rate changed from 1200 to 19200 with
release of CPU software revision 7.1.
1. Make sure power is turned OFF on the
EN | 9
Function
Baud Rate
1
19200 (Factory Default Setting)
9600
4800
2400
1200
600
Reserved
Reserved
Handshaking
Disable
Enable (Factory Default Setting)
Alarm Port Expander Mode
Alarm Port Expander
Reserved
Alarm Port Expander Hub
Reserved
Reserved
Function
Allegiant
System Baud Rate
®
19200 (Factory Default Setting)
9600
4800
2400
1200
57600 (Recommended for Hub
Mode)
Reserved
Reserved
Handshaking
Disable (Factory Default Setting)
Enable
Stop Bits
1 Stop Bit (Factory Default
Setting)
2 Stop Bit
Reserved
1

Advertisement

Table of Contents
loading