CIRCUIT DIAGRAM Models : ABU18RULX, ABU24RULX ROOM TEMPERATURE THERMISTOR PIPE TEMPERATURE THERMISTOR FAN MOTOR WHITE BROWN WHITE CAPACITOR ORANGE YELLOW BROWN WHITE BLUE STEP MOTOR ORANGE PURPLE ( UP / DOWN ) YELLOW GRAY WHITE BLACK WHITE BROWN STEP MOTOR...
Page 7
Model : AOU18RLX, AOU24RLX OUTDOOR TEMPERATURE BLACK THERMISTOR PIPE TEMPERATURE BLUE THERMISTOR COMPRESSOR TEMPERATURE BROWN BROWN THERMISTOR DISCHARG TEMPERATURE THERMISTOR BLACK HEAT SINK TEMPERATURE THERMISTOR EMI FILTER CN21 CN22 CN23 CN26 CN25 CONNECTOR HIGH PRESSURE SWITCH CN37 W305 WHITE WHITE COMPRESSOR W304 FUSE...
ERROR CONTENTS (Indoor unit) Operation can be checked by lighting and flashing of the display section OPERATION, TIMER, and VERTICAL SWING lamps. Perform judgment in accordance with the following. VERTICAL SWING lamp (Orange) TIMER lamp (Green) OPERATION lamp (Red) MANUAL AUTO SWING SWING...
Page 13
ERROR CONTENTS (outdoor unit) SPECIAL INSTALLATION 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. SETTING PUMP DOWN (Refrigerant collecting operation) 2. OUTDOOR UNIT LEDS When a malfunction occurs in the outdoor unit, the LED on Perform the following procedures to collect the refrigerant the circuit board lights to indicate the error.
Page 14
D I S A S S E M B L Y A S S E M B L Y Models : ABU18RULX, ABU24RULX 653-2 365-2 365-1 870-1 365-2 870-1 653-2 365-1 2005.12.28...
OUTDOOR UNIT Part No. Ref. Ord. Description Q'ty AOU18RLX AOU24RLX Top Panel Sub Assy 9374417025 9374417025 Front Panel 9374094066 9374094066 Fan Guard 9374330010 9374330010 Grip Side 9374173013 9374173013 Service Panel Sub Assy 9374415038 9374415038 Right Panel Sub Assy 9374416073 9374416073 Emblem Rear 9351355005 9351355005...
Page 28
STANDARD ACCESSORIES The following installation parts are furnished. Use them as required. INDOOR UNIT ACCESSORIES Name and Shape Q'ty Application Part No. Cosmetic Panel-L 9358536018 Cosmetic Panel-R 9358535011 Tapping screw ( 4 x 10) 301171164104 Installation template For positioning the indoor unit. For under ceiling type.
REMOTE CONTROL UNIT Name and Shape Q'ty Application Part No. Remote control unit Use for air conditioner operation 9371190051 (AR-JW5) Battery (penlight) 0600185534 For remote control unit Remote control unit holder For mounting the remote control 9305642014 unit Tapping screw 3 x 12) For remote control unit holder 301141533125...