Condensate piping to floor drain
Tankless Gas
Water Heater
DO NOT ADD
ANY VALVES
Slope pipe downwards
1/4" per foot.
Floor drain
line from clogging or freezing.
26
Electrolux
Condensing
1/2" PVC pipe
The end of the drain pipe
must have an air gap.
MAINTAIN CLEARANCE
Condensate piping with pump
Electrolux
Condensing
Tankless Gas
Water Heater
DO NOT ADD
ANY VALVES
1/2" PVC pipe
1/2" PVC elbow
Slope pipe downwards
1/4" per foot.
The end of the drain pipe
must have an air gap.
3/8" ID tubing*
Condensate pump
* Install tubing according to pump
manufacturer's instructions.