Siemens REV23 User Manual

Siemens REV23 User Manual

Self-learning room temperature controller, 5 operating modes, heating / cooling functions and menu selection via roller selector

Advertisement

Use
CE1N2264en
23.04.2002
Self-learning Room
Temperature Controller
5 operating modes, heating / cooling functions and menu selection via roller selector
• Mains-independent room temperature controller
• Straightforward, self-explanatory menu selection via roller selector
• Self-learning 2-position controller providing PID mode (patented)
• Choice of operating modes:
automatic with maximum 3 heating or cooling periods, continuously comfort
mode, continuously economy mode, frost protection with one 24-hour operat-
ing mode and one heating or cooling period
• In automatic mode, one temperature setpoint can be adjusted for each heating
or cooling period
• Control of cooling equipment
For the control of the room temperature in:
• Apartments, single-family or holiday houses
• Offices, individual rooms, consulting rooms or commercially used spaces
For control of the following pieces of equipment:
• Solenoid valves of instantaneous water heaters
• Solenoid valves of atmospheric gas burners
• Forced draft gas or oil burners
• Circulating pumps in heating systems, zone valves
• Electric direct heating systems or fans of electric storage heaters
• Thermic actuators
• Cooling and refrigeration equipment
Siemens Building Technologies
HVAC Products
2
264
REV23

Advertisement

Table of Contents
loading

Summary of Contents for Siemens REV23

  • Page 1 • Forced draft gas or oil burners • Circulating pumps in heating systems, zone valves • Electric direct heating systems or fans of electric storage heaters • Thermic actuators • Cooling and refrigeration equipment Siemens Building Technologies CE1N2264en HVAC Products 23.04.2002...
  • Page 2: Functions

    Roller selector for the menu, submenu and settings Confirm by pressing Leaving the current menu level and returning to the menu level previously active (the settings currently displayed will be ac- cepted) 2/12 Siemens Building Technologies Room Temperature Controller REV23 CE1N2264en HVAC Products 23.04.2002...
  • Page 3: User Settings

    Factory settings – heating / cooling Temperature Main menu Submenu Setpoint comfort mode 19 °C 23 °C Setpoint economy mode 16 °C 29 °C Setpoint frost 5 °C 35 °C or overtemperature protection 3/12 Siemens Building Technologies Room Temperature Controller REV23 CE1N2264en HVAC Products 23.04.2002...
  • Page 4 In the frost or overtemperature protection mode, the room temperature is constantly monitored. If it falls (rises) below (above) the adjusted setpoint, heating / cooling is switched on to maintain the adjusted frost or overtemperature protection setpoint tem- perature 4/12 Siemens Building Technologies Room Temperature Controller REV23 CE1N2264en HVAC Products 23.04.2002...
  • Page 5 ) during your absence. This will enable the controller to maintain the re- quired temperature for a period of up to 99 days. Every midnight, the counter subtracts one day. 5/12 Siemens Building Technologies Room Temperature Controller REV23 CE1N2264en HVAC Products 23.04.2002...
  • Page 6 00.00 24.00 5 35 Mo-Su 10 30 Absence 12 30 Factory settings heating engineer level Setpoint limitation PID mode, self-learning Optimum start control Periodic pump run Off Heating active 6/12 Siemens Building Technologies Room Temperature Controller REV23 CE1N2264en HVAC Products 23.04.2002...
  • Page 7 Starting point of optimum start control Control The REV23 is a 2-position controller providing PID mode. The room temperature is controlled through the cycling switching of an actuating device. The controller generates the positioning signals depending on the deviation of the ad- justable setpoint from the actual value acquired by the built-in temperature sensor.
  • Page 8 Controller The REV23 has a plastic housing with a large display and easily accessible operating elements. The controller is removed from its base by sliding it upward. It is thus possi- ble to replace the two 1.5 V alkaline batteries type AA in the compartment at the rear of...
  • Page 9 • If the displayed room temperature does not correspond to the effective room tem- perature, the temperature sensor should be recalibrated (refer to “Sensor calibration”) 9/12 Siemens Building Technologies Room Temperature Controller REV23 CE1N2264en HVAC Products 23.04.2002...
  • Page 10 < 93 % r.h. Mechanism class 2M2 to IEC 60 721-3 Weight Incl. package 0.33 kg Housing signal-white RAL9003 Color Base grey RAL7038 Size Housing 140 x 104.5 x 30 mm 10/12 Siemens Building Technologies Room Temperature Controller REV23 CE1N2264en HVAC Products 23.04.2002...
  • Page 11: Application Examples

    Connection diagram Live AC 24…250 V Room temperature controller REV23 N.O. contact, AC 24…250 V / 6 (2.5) A Remote operating device (potentialfree) N.C. contact, AC 24…250 V / 6 (2.5) A Signal “remote operation” Circulating pump Signal “remote operation”...
  • Page 12 Cooling equipment Limit thermostat Safety limit thermostat Circulating pump Room temperature controller REV23 3-port valve with manual adjustment Solenoid valve Motorized 3-port valve Motorized 2-port valve 2261S04 Circulating pump with precontrol via manual mixing valve Dimensions 11.75 83.50 ã2001 Siemens Building Technologies AG...

Table of Contents