  • Page 1 Operating and installation instructions LC 89950 GB...
  • Page 2 Fig. 1 Abb. 1 ELECTR. mind. mind.
  • Page 3: Appliance Description

    Instructions for use: Appliance description Operating modes Chimney This can be achieved if the combustion air panelling is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall Light box or by other technical procedures such switches switches as reciprocal interlocking.
  • Page 4: Before Using For The First Time

    Before using for the first time Important notes: The Instructions for Use apply to several Before using your appliance for the first time, please read these Instructions for versions of this appliance. Accordingly, Use carefully. They contain important you may find descriptions of individual information concerning your personal features that do not apply to your safety as well as on use and care of the...
  • Page 5: Operating Procedure

    Operating procedure Switching the fan OFF: The most effective method of removing Ü vapours produced during cooking is to: Keep pressing the – button until the fan switches off. Switch the ventilator ON The displayed goes out shortly as soon as you begin cooking. afterwards.
  • Page 6: Filters And Maintenance

    Filters and maintenance Grease filters: Removing and inserting the metal grease filters: Metal filters are used to trap the greasy Warning: The halogen bulbs must be element of the vapours that develop switched off and cool. during cooking. 1. Rotate the two catches on the grease The filter mats are made from non- filter and remove the grease filter.
  • Page 7 Filters and maintenance Activated carbon filter: For neutralizing odours in recirculating Saturation indicator: ã mode. When the activated carbon filter reaches saturation point, an acoustic signal is sounded for 10 seconds after the fan has switched off, and a appears in the ã...
  • Page 8: Cleaning And Care

    Cleaning and care Replacing the light bulbs Disconnect the extractor hood from the 1. Switch off the extractor hood and pull electricity supply by pulling out the out the mains plug or switch off the mains plug or switching it off at the fuse electricity supply at the fuse box.
  • Page 9: If You Encounter A Problem

    Setting the saturation indicator If you encounter a problem If an appears in the display: If it becomes necessary to change the ã operating mode (exhaust-air/recirculating See "Filters and maintenance" Section. mode), the saturation indicator for the filters If is not possible to operate the extractor must also be altered (see Installation hood: Instructions).
  • Page 10: Installation Instructions

    Installation Instructions: Important information Additional information concerning gas Old appliances are not worthless cookers: rubbish. Valuable raw materials can be reclaimed by recycling old appliances. When installing gas hotplates, comply Before disposing of your old appliance, with the relevant national statutory render it unusable.
  • Page 11: Prior To Installation

    Prior to installation Exhaust-air mode mind. 36 700-1080 The exhaust air is discharged upwards This can be achieved if combustion air can through a ventilation shaft or directly flow through non-lockable openings, e.g. in through the outside wall into the open. doors, windows and via the air- intake/exhaust-air wall box or by other Exhaust air should neither be directed...
  • Page 12: Circulating-Air Mode

    Prior to installation Connecting a l 150 mm exhaust-air For optimum extractor hood efficiency: pipe: Short, smooth air exhaust pipe. Mount the pipe directly onto the air As few bends in the pipe as possible. outlet on the hood. Diameter of pipe to be as large as possible and no tight bends in pipe.
  • Page 13: Electrical Connection

    Prior to installation Electrical connection WARNING: THIS APPLIANCE MUST BE Preparing the wall EARTHED The wall must be flat and perpendicular. IMPORTANT: Fitting a Different Plug: Ensure that the wall is capable of The wires in the mains lead are coloured in providing a firm hold for mounting accordance with the following code: screws and plugs.
  • Page 14: Installation

    Installation This extractor hood is intended to be Note: Take into account any special mounted onto the kitchen wall. accessories that are going to be fitted. 1. Remove the grease filter 5. Screw on the upper and the two lower (refer to Operating Instructions).
  • Page 15 Installation 07. Screw in lower screws (hex screws). 13. Insert the complete flue duct at an angle into the glass shield and swivel If any pressure is exerted on the backwards. glass screen when tightening the Warning: The holes in the flue duct screws it could lead to glass breakage.
  • Page 16 LZ51550 360732 5750 206 985 Siemens-Electrogeräte GmbH Printed in Germany 0404 Es.