Miele DG 4064 Installation Instructions Manual

Steam oven

Advertisement

Quick Links

Installation instructions

Steam oven
DG 4064
DG 4064 L
GiZ
To avoid the risk of accidents or
damage to the appliance it is
essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 06 786 800

Advertisement

Table of Contents
loading

Summary of Contents for Miele DG 4064

  • Page 1: Installation Instructions

    Installation instructions Steam oven DG 4064 DG 4064 L To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time. M.-Nr. 06 786 800...
  • Page 3: Table Of Contents

    DG 4064 in 380 mm tall housing unit........6 DG 4064 and AB 45-7 in 450 mm tall housing unit ......8 DG 4064 L in 380 mm tall housing unit .
  • Page 4: Safety Instructions

    Safety instructions Water Authority and Building The water inlet hose must be flushed Regulations must also be through before using the appliance observed. for the first time, and thereafter every The stopcock for the steam oven time the water inlet hose is re-fitted. water inlet must be located so that This is to remove any deposits which it is easily accessible after the...
  • Page 5 Safety instructions A cut-out a, as illustrated below, is Keep these instructions in a safe place required in the housing unit for and pass them on to any future feeding the water inlet and outlet user/owner of the appliance. through. This is to ensure that there is All dimensions in this instruction booklet adequate space for any movement in are given in mm.
  • Page 6: Appliance And Building-In Dimensions

    Appliance and building-in dimensions DG 4064 in 380 mm tall housing unit 2 0 0 c m 5 5 5 - 5 6 8 5 6 0 2 7 0 - 5 6 5 6 0...
  • Page 7 Appliance and building-in dimensions a Cut-out in the housing unit for feeding the water inlet and outlet hoses through b Isolator switch position. Important UK: Do not position the isolator behind the appliance! c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!
  • Page 8: Dg 4064 And Ab 45-7 In 450 Mm Tall Housing Unit

    Appliance and building-in dimensions DG 4064 and AB 45-7 in 450 mm tall housing unit 2 0 0 c m 5 9 5 5 5 5 - 5 6 8 5 6 0 2 7 0 - 5 6 5 6 0...
  • Page 9 Appliance and building-in dimensions a Cut-out in the housing unit for feeding the water inlet and outlet hoses through b Isolator switch position. Important UK: Do not position the isolator behind the appliance! c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!
  • Page 10: Dg 4064 L In 380 Mm Tall Housing Unit

    Appliance and building-in dimensions DG 4064 L in 380 mm tall housing unit 2 0 0 c m 5 5 5 5 5 2 - 5 6 8 5 6 0 2 7 0 - 5 6 5 6 0...
  • Page 11 Appliance and building-in dimensions a Cut-out in thehousing unit for feeding the water inlet and outlet hoses through b Isolator switch position. Important UK: Do not position the isolator behind the appliance! c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!
  • Page 12: Dg 4064 L And Ab 45-7 In 450 Mm Tall Housing Unit

    Appliance and building-in dimensions DG 4064 L and AB 45-7 in 450 mm tall housing unit 2 0 0 c m 5 9 5 5 5 5 5 5 2 - 5 6 8 5 6 0 2 7 0...
  • Page 13 Appliance and building-in dimensions a Cut-out in the housing unit for feeding the water inlet and outlet hoses through b Isolator switch position. Important UK: Do not position the isolator behind the appliance! c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!
  • Page 14: Installation

    ^ Feed the water inlet and drainage hoses through the cut-out a in the housing unit. See "Safety DG 4064 L instructions". ^ Push the appliance into the recess as far as it will go, making sure that the...
  • Page 15: Electrical Connection

    Electrical connection Connection should be made via a All electrical work should be carried suitable isolator which complies with out by a suitably qualified and national and local safety regulations, competent person, in strict and the On/Off switch should be easily accordance with current local and accessible after the appliance has national safety regulations (BS 7671...
  • Page 16: Connection Cable

    Electrical connection WARNING THIS APPLIANCE MUST BE EARTHED The electrical safety of this appliance can only be guaranteed when continuity is complete between it and an effective earthing system, which complies with current local and national safety regulations. It is most important that this basic safety requirement is present and regularly tested and where there is any doubt, the electrical wiring...
  • Page 17: Connection Diagram

    Electrical connection Wiring diagram N.B. This appliance is supplied single phase only in the UK.
  • Page 18: Plumbing

    7.5 metres using hose accessible (e.g. in a neighbouring extensions. These are available as base unit). optional accessories from the Miele Spare Parts Department, and must The person installing the appliance not be shortened or damaged. is responsible for ensuring its correct operation.
  • Page 19: Connection To Drainage

    The drain hose must not be shortened. The hose may be lengthened (horizontally) up to a maximum of 7.5 metres using hose extensions. These are available as optional accessories from the Miele Spare Parts Department and must not be shortened or damaged.
  • Page 20 Alteration rights reserved / 1106 M.-Nr. 06 786 800 / 02 en - –...

This manual is also suitable for:

Dg 4064 l

Table of Contents