FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
Never store anything on, near, or in contact with the
furnace, such as:
1. Spray or aerosol cans, rags, brooms, dust mops,
vacuum cleaners, or other cleaning tools.
2. Soap powders, bleaches, waxes or other cleaning
compounds,
plastic or plastic containers,
gasoline,
kerosene, cigarette lighter fluid, dry cleaning fluids, or
other volatile fluids.
3. Paint thinners
and other
painting
compounds,
paper bags, or other paper products.
ELECTRICAL SHOCK AND FIRE HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Turn off the gas and electrical supplies to the unit and
install
a
lock
out
tag
before
performing
any
maintenance
or
service.
Follow
the
operating
instructions on the label attached to the furnace.
CARBON
MONOXIDE
POISONING
AND
FIRE
HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
Never operate unit without a filter or with filter access
door removed.
CUT HAZARD
Failure to follow this caution may result in personal
injury.
Sheet metal parts may have sharp edges or burrs.
Use care and wear appropriate
protective
clothing,
safety glasses and gloves when handling parts and
servicing furnaces.
The minimum maintenance on this furnace is as follows:
1. Check and clean air filter each month or more frequently if
required. Replace if torn.
2. Check
blower
motor
and
wheel for cleanliness
each
heating and cooling season. Clean as necessary.
3. Check electrical connections for tightness and controls for
proper operation each heating season. Service as necessary.
4. Inspect burner compartment
before each heating season
for rust, corrosion, soot or excessive dust. If necessary, have
furnace and burner serviced by a qualified service agency.
5. Inspect the vent pipe/vent
system
before each heating
season for rust, corrosion, water leakage, sagging pipes or
broken fittings.
Have vent pipes/vent
system serviced by a
qualified service agency.
6. Inspect any accessories attached to the furnace such as a
humidifier or electronic
air cleaner. Perform any service or
maintenance
to the accessories
as recommended
in the
accessory instructions.
CLEANING AND/OR REPLACING AIR FILTER
The
air filter
arrangement
will
vary
depending
on the
application. The filter is exterior to the furnace casing.
NOTE:
If the filter has an airflow direction arrow, the arrow
must point towards the blower.
CUT HAZARD
Failure to follow this caution may result in personal
injury.
Sheet metal parts may have sharp edges or burrs.
Use care and wear appropriate
protective clothing,
safety glasses and gloves when handling parts and
servicing furnaces.
BLOWER MOTOR AND WHEEL
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Blower
access
door switch
opens 115-v
power to
control.
No component
operation
can occur
unless
switch is closed. Caution must be taken when manually
closing this switch for service purposes.
NOTE:
The blower wheel should not be dropped or bent as
balance will be affected.
The following
steps should be performed
by a qualified
service agency.
To ensure long life and high efficiency, clean accumulated
dirt
and grease from blower wheel and motor annually.
The
inducer and
blower
motors
are pre-lubricated
and
require
no additional
lubrication.
These
motors
can be
identified
by the absence
of oil ports on each end of the
motor.
Clean blower motor and wheel as follows:
1. Turn off electrical supply to furnace.
2. Remove outer door.
3. For downflow or horizontal furnaces having vent pipes
within the furnace that pass in front of the blower ac-
cess door:
a. Disconnect vent connector from furnace vent elbow.
b. Disconnect and remove short piece of vent pipe
from within furnace.
4. Remove 2 screws from blower access door and re-
move blower access door.
5. All factory wires can be left connected, but field thermo-
stat connections
may need to be disconnected
de-
pending on their length and routing.
6. Remove 2 screws holding blower assembly to blower
deck and slide blower assembly out of furnace.
7. Clean blower wheel and motor using a vacuum with
soft brush attachment.
Blower wheel blades may be
cleaned with a small paint or flux brush. Do not remove
or disturb balance
weights
(clips) on blower wheel
blades.
40