OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. The equipment complies with requirements of the Technical Regulation, in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment.
Operating Method........9 preventive care on your part can save you a great deal Wireless Remote Controller....10 of time and money over the life of your air conditioner. Operation Mode........11 You'll find many answers to common problems in the Healthy Dehumidification Operation..12 chart of troubleshooting tips.
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
Page 4
• It may cause corrosion on the product. • A bad connection may cause water leakage. • To avoid vibration or noise. • It may cause a problem for your neighbors • Low refrigerant levels may cause failure of and hence dispute. product. 4 Room Air Conditioner...
Page 5
• There is risk of fire or product failure. • They may burn or explode. If the liquid from the batteries gets onto Do not let the air conditioner run for a Do not expose your skin or kids or your skin or clothes, wash it well with long time when the humidity is very high plants to the cool or hot air draft.
Product Introduction Product Introduction Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type. Indoor Units Standard Split Type Rational Type Display panel LED indicators Display panel LED indicators Air inlet Air inlet Plasma filter...
* In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency. Outdoor Unit Air intake vents Connecting wires Refrigerant pipes Air outlet vents Drain hose Base plate 8 Room Air Conditioner...
Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1.
Pressing the 2 F button activates the blue printed function of the respective button. To cancel the function press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds. 10 Room Air Conditioner...
Operating Instructions Operation Mode Press the START/STOP BUTTON to turn the unit on. The unit will respond with a beep. Open the door of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
But during this operation the controller changes the operation mode automatically to keep the temperature within ±2°C with respect to the setting temperature. Auto Changeover To run this operation follow steps 1, 2, 3, and 4. (See operation mode) 12 Room Air Conditioner...
Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.
During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep". If you want to stop the operation, re-press the button. 14 Room Air Conditioner...
2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the SLEEP MODE AUTO BUTTON while aiming at air conditioner. 3. • (In case of non-Inverter Model) Make sure the sleep mode LED lights up.
This function is useful in the situation of power failure. When power regains after a failure this feature restore the previous operating condition and the air conditioner will run in the same settings. NOTE This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds.
Never use any of these • Water hotter than 40°C. It may cause deformation and discoloration. • Volatile substances. They may damage the surface of the air conditioner. Air Filters The air filters behind the front panel / grill should be checked and cleaned once in every 2 weeks or more often if necessary.
Page 18
Type 1: Open the front panel as shown. Then pull the filter tab slightly forward to remove the air filter. After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward. Deodorizer filter Plasma filter 18 Room Air Conditioner...
This is not good for the health and Do not let direct sunshine enter Adjust the vertical and horizontal wastes electricity. the room when the air conditioner airflow direction to ensure a is in operation. uniform temperature in the room.
Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Possible Causes What To Do Call the service immediately in the following situations User must carry routine checkup & cleaning to avoid unitʼs poor performance.