GE JGP633 Installation Instructions Manual page 6

36" sealed gas cooktop
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
INSTALLATION--GAS CONNECTIONS
r_
PROVIDE ADEQUATE
GAS SUPPLY
This cooktop
is designed to operate on natural gas
at 4" of water column manifold
pressure and 7" of
water column (W.C.) supply pressure. It is shipped
from the factory set for natural gas. The convertible
pressure regulator
supplied with the unit must
be connected
in series with the manifold
of the
cooktop and must remain in series with the supply
line regardless of whether
natural or LP. gas is
being used.
FOR PROPER OPERATION, THE MAXIMUH INLET
PRESSURETO THE REGULATOR MUST BE NO HaRE
THAN 14" OF WATER COLUMN PRESSURE.For
checking the regulator, the inlet pressure must
be at least 1" W.C.. (or 3.4 KPA) greater than the
regulator
output setting. If the regulator
is set for 4"
W.C. of water column pressure, the inlet pressure
must be at least 5" W.C. If the regulator
is set for
10" W.C., the inlet pressure must be at least 11"
W.C.. The gas supply line to the cooktop should be
1/2" or 3/4" pipe.
J_
INSTALL REGULATOR
NEVER REUSE OLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.
A WARNING: Never reuse o ld
flexible connectors.
The use of old flexible
connectors
can cause gas leaks and personal
injury. Always use new flexible connectors
when
installing a gas appliance.
Screw a section of pipe onto
the inlet end of the pressure
regulator
and install the
coupling.
Pressure __[_
Regulator
Coupling
To reduce the likelihood of gas leaks, applyl-_lon
tape or a thread compound
approved
for use with
LP or Natural gases to all threaded
connections.
r_
INSTALL REGULATOR ONTO
BURNER BOX BOTTOM
Screw the regulator
onto the burner
box bottom
pipe
connection.
Hake sure the
top of the regulator
is facing towards
the
cabinet front, easily
accessible through
the cabinet doors.
I
I
Pressure ___
Regulator
Coupling _l
Shut-Off
_l Valve _'_
l]J
U
1
Electrical
I
Outlet 12"
I
Below
Countertop
_]
COMPLETE CONNECTION
WITH A
COUPLING
Complete the
connection
between
the regulator,
pipe
coupling, and
the shut-off valve.
I
I
Pressure
Regulator
Coupling _l
_
Shut-Off
Valve
Jw
Ll
i\
II Electrical
I Outlet 12"
I
Below
Countertop

Advertisement