Checking the
burner nozzles
Checking the
bypass nozzles
1. Open the locking device for the gas connection.
Check each nozzle individually for leaks.
2. To do this, hold the opening of the burner nozzle
shut with a finger or carefully lock it using a special
device.
3. Moisten the area around the nozzle with foam.
4. Push in the control knob and turn it anti clockwise.
Gas is supplied in this way.
If the foam dissolves or gas escapes, see "If gas
escapes".
1. Open the locking device for the gas connection.
Check each bypass nozzle individually for leaks.
2. To do this, hold the opening of the burner nozzle
shut with a finger and carefully lock it using a
special device.
3. Moisten the area around the bypass nozzle of the
respective burner with foam.
4. Press in the shaft of the tap or cup and turn it
anti clockwise. Gas is supplied.
If the foam dissolves or gas escapes, see "If gas
escapes".