Instructions for the installer
If this is the only gas appliance in the room, it is necessary to install a hood so as to expel vitiated
air naturally and directly, with a rectilinear vertical duct at least twice as long as its diameter and
2
having a minimum section of at least 100 cm
.
For the essential air intake into the room, it is necessary to prepare a similar opening of at least
2
100 cm
that communicates directly outside, situated close to floor level so as not to be obstructed
from either inside or outside and so as not to disturb the combustion of the burners and the correct
expelling of vitiated air and with a height difference from the exit opening of at least 180 cm.
electric fan
3
Remember that the quantity of air necessary for combustion must not be lower than 2 m
/h per kW
of power (see total power in kW shown on the appliance plate).
In all other cases, i.e. when other gas appliances are present in the same room, or, if it is not
possible to have natural direct ventilation, it is necessary to create natural, indirect ventilation or
forced ventilation: for this type of operation, it is necessary to contact a qualified technician
for installing and creating the ventilation system in strict compliance with the guidelines set
out in current standards.
The openings should be positioned so as not to allow the formation of any unpleasant air current
for the occupants. Furthermore, it is forbidden to use flues already used by other appliances to
expel products of combustion.

12.5 Gas connection

We recommend checking that the appliance is properly set up for the type of
gas distributed. The connection to the gas pipes must be made in a
workmanlike manner, in compliance with current standards that prescribe the
installation of a safety tap at the end of the pipe. The threaded ½" gas
connection pipe is located at the rear on the right hand side of the appliance.
For butane and propane, a pressure reducer conforming to standards regulations in force should
be prepared. The seals must conform to standards regulations in force.
Once the gas has been connected, check the seal of the unions with a soap and water solution.
For Town Gas a separate gas pressure regulator must be intalled with the cooker.