GE 2900 Series Product Manual page 17

Packaged terminal air conditioners
Hide thumbs Also See for 2900 Series:
Table of Contents

Advertisement

Field Wiring Terminal
R
— 24V AC
Resistance Heat Models
GH — High-Speed Fan
Y
— Compressor
C
— Common - Ground
Heat Pump Models
Remote Thermostat Control Selection Chart For Zoneline Packaged Terminal Units
Zoneline Series
Thermostat Model
2900
900 and 5800
Thermostat wire size – up to 60 feet AWG20 – up to 66 feet AWG18
Common — Ground
White — Heater
Yellow — Compressor
Black — Not Used On 2800
Green — High-Speed Fan
Green — Low-Speed Fan
Red — 24V AC
CDC Terminal
GL — Low-Speed Fan
B
— Reversing Valve
W — Heater
Common — Ground
White — Heater
Yellow — Compressor
Black — Reversing Valve
Green — High-Speed Fan
Green — Low-Speed Fan
Red — 24V AC
RAK16A1
Mechanical
RAK164D1
RAK164P1
Digital Programmable
RAK148D1
RAK148P1
Digital Programmable
Type
Function
Cooling and Heating
Digital
Digital
Single Stage Cooling –
2 Stage Heating
ge.com
Low-Voltage Conductors
4
5
5
6
6
17

Advertisement

Table of Contents
loading