GE GNSV70RBL Owner's Manual And Installation Instructions

General electric water filtration system owner's manual and installation instructions

Advertisement

GEAppliances.com
. . . . . . . . . . . . .2
. . . . . . . . . . . . .3-5
Installation Instructions
Battery Installation . . . . . . . . . . . . . . . .11
Faucet Installation . . . . . . . . . . . . . . . .7, 8
Feed Water Supply . . . . . . . . . . . . . . .6, 7
Filter Replacement . . . . . . . . . . . . . . . . .12
Flush Procedure . . . . . . . . . . . . . . . . . . .12
Installing the Tubing . . . . . . . . . . . . . . .11
System Installation . . . . . . . . . . . . . .9, 10
Consumer Support
Consumer Support . . . . . . . .Back Cover
Parts List/Catalog . . . . . . . . . . . . . . . . . .14
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .15
GNSV70RBL and GNSV75RWW are Tested and Certified
by NSF International against NSF/ANSI Standard 42 for
the reduction of Chlorine: Taste and Odor and Particulate
Class I and Standard 53 for the reduction of Lead, Cyst,
Turbidity, Asbestos, Mercury, Lindane, Atrazine, Benzene
and VOC.
. . . .6-12
. . . . . . . . . .13
215C1219P001
Owner's Manual and
49-50234-3
02-09 JR

Advertisement

Table of Contents
loading

Summary of Contents for GE GNSV70RBL

  • Page 1: Table Of Contents

    Warranty ......15 GNSV70RBL and GNSV75RWW are Tested and Certified by NSF International against NSF/ANSI Standard 42 for...
  • Page 2: Safety Instructions

    IMPORTANT SAFETY INFORMATION. WARNING: Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage. ■ Check with your local public works department for plumbing codes. You must follow their guidelines as you install the Water Filtration system.
  • Page 3: System Overview

    This system conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and sustained by test data. See Performance Data Sheet for details. Installation Overview Locate the drinking water system on the cold water supply pipe, under the kitchen and/or bathroom sink, to filter the cold drinking water. Filtered Water Faucet...
  • Page 4: Performance Data Sheet

    Performance Data Sheet. SmartWater Filtration System GNSV70RBL and GNSV75RWW Using Filter FQSVF ■ This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
  • Page 5 Performance Data Sheet. Contaminant Alachlor Atrazine Benzene Carbofuran Carbon Tetrachloride Chlorobenzene Chloropicrin 2,4-D Dibromochloropropane (DBCP) o-Dichlorobenzene p-Dichlorobenzene 1,2-Dichloroethane 1,1-Dichloroethylene cis-1,2-Dichloroethylene trans-1,2-Dichloroethylene 1,2-Dichloropropane cis-1,3-Dichloropropylene Dinoseb Endrin Ethylbenzene Ethylene Dibromide (EDB) Haloacetonitriles (HAN): Bromochloroacetonitrile Dibromoacetonitrile Dichloroacetonitrile Trichloroacetonitrile Influent challenge levels are average influent concentrations determined in surrogate qualification testing. μg/L means Micrograms Per Liter.
  • Page 6: Installation Instructions

    • Feed water adapter • Faucet assembly with electronic base monitor and tubing Faucet Mount Filtration System – GNSV70RBL and GNSV75RWW COLD WATER SUPPLY FITTING A. PREFERRED INSTALLATION (Utilizing existing kitchen sink water supply valve and flexible faucet tubing) A typical connection using the included water supply fitting is shown in the illustration below.
  • Page 7: Faucet Installation

    COLD WATER SUPPLY FITTING B. OPTIONAL HOME INSTALLATION (Where codes permit) Saddle Valve: Saddle valve must be able to connect with 1/4-inch tubing supplied with the system. Not supplied with product; check your local hardware or home service store for product.
  • Page 8 INSTALL THE FAUCET (CONT.) 6. Feed the water tube up through the faucet base. Then push the tube into the fitting on the bottom of the faucet body. It should go in about 3/4″. Pull tube slightly to make sure it is secure. Faucet Body Base Toggle Screw...
  • Page 9: System Installation

    MOUNTING SYSTEM INSTALLATION Pick a location under the sink to mount the system. Location should be easily accessible, with clearance between the bottom of the filter canisters and the floor or bottom of the cabinet; any less will result in difficulty of removing filter canisters (see Fig.
  • Page 10 Installation Instructions MOUNTING SYSTEM INSTALLATION (CONT.) Mounting System to Screws Installed in Wall 1. Remove shrink wrap from filter system. 2. Hang the system on the previously installed screws using the openings on the back of the unit (Fig. 7). 3.
  • Page 11: Battery Installation

    INSTALLING THE TUBING 1. Measure 3/4″ from the end of each remaining piece of tubing (faucet end and inlet end) and mark with a pencil (Fig. 8). (Check for roundness, smoothness, cuts, nicks, flat spots and sharp edges. It may be necessary to recut the tubing.) 3/4″...
  • Page 12: Filter Replacement

    (Canada–French). Installation Instructions FLUSH PROCEDURE Whenever water of unknown quality is passed through the GE Water Filtration system, the filter canisters should be discarded and the filtration system flushed. WARNING: microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
  • Page 13: Troubleshooting Tips

    Before you call for service… Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes Water contains tiny New filter canisters contain black particles activated carbon. Water has air bubbles Air in system after installation.
  • Page 14: Parts List/Catalog

    Parts List. General Electric parts catalog. ITEM GE CAT. NO. WS19X10016 WS19X10015 WS22X10045 FQSVF WS03X10046 WS07X10020 WS60X10016 WS15X10068 WS15X10069 WS10X10039 WS10X10040 49-50234 GNSV70RBL, GNSV75RWW To obtain replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada- English), 800.361.3869 (Canada-French) DESCRIPTION MANIFOLD ASSEMBLY COVER, DUAL MANIFOLD ELBOW &...
  • Page 15: Warranty

    This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service.
  • Page 16 Caution must be exercised, since improper servicing may cause unsafe operation. Contact Us If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: Register Your Appliance Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and...

This manual is also suitable for:

Gnsv75rww

Table of Contents