Chapter 6: Advanced setup

Configuring remote alert

The TVR 30 can send alarm notifications to a remote PC using compatible monitoring
software. Use the Remote Alert screen to define settings that allow the TVR 30 to
communicate with the remote PC and to enable this feature.
In addition, the DVR sends a signal to the remote PC every two minutes to indicate
that the DVR is still active.
To configure remote alert:
1. Click Alarms on the main menu to display the Alarms screen.
2. Click Remote Alert Setup to display the Remote Alert screen.
3. Select an alert set.
4. Select On in the Alert Notification box to enable alert notification to the remote PC.
5. Enter the PC's IP address in the Alert IP edit box.
6. Enter the PC's port in the Alert Port box.

Enabling the alarm buzzer

In the Alarms screen, select On in the Buzzer box to enable alarm buzzer. An audible
sound is emitted when an alarm is triggered.

Camera alarm settings

Use the Camera Setting screen to define camera alarm settings.
To define camera alarm settings:
1. Click Alarms on the main menu to display the Alarms screen.
2. Click Camera Setting Setup to display the Camera Setting screen.
3. Select a camera in the Current Camera box.
4. Select an alarm input in the Alarm Input box.
5. Select an output in the Relay Output box.
6. Select On in the Video Detection box to detect video loss.

Prealarm and post alarm seconds

In the Prealarm box, enter the prealarm seconds. The prealarm option defines the
number of seconds recorded before a motion or external alarm is triggered and
includes the alarm data.