6 COMMUNICATIONS
Table 6–1: 489 MEMORY MAP (SHEET 20 OF 24)
ADDR NAME
MONITORING / RUNNING HOUR SETUP
2AC0
INITIAL GEN. RUNNING HOUR
2AC2
GEN. RUNNING HOUR ALARM
2AC3
ASSIGN ALARM RELAYS (2-5)
2AC4
GEN. RUNNING HOUR LIMIT
2AC6
RESERVED
ANALOG I/O / ANALOG OUTPUT 1
2B00
ANALOG OUTPUT 1
ANALOG I/O / ANALOG OUTPUT 2
2B01
ANALOG OUTPUT 2
ANALOG I/O / ANALOG OUTPUT 3
2B02
ANALOG OUTPUT 3
ANALOG I/O / ANALOG OUTPUT 4
2B03
ANALOG OUTPUT 4
ANALOG I/O / ANALOG OUTPUTS
2B04
IA OUTPUT CURRENT MIN
2B05
IA OUTPUT CURRENT MAX
2B06
IB OUTPUT CURRENT MIN
2B07
IB OUTPUT CURRENT MAX
2B08
IC OUTPUT CURRENT MIN
2B09
IC OUTPUT CURRENT MAX
2B0A
AVG OUTPUT CURRENT MIN
2B0B
AVG OUTPUT CURRENT MAX
2B0C
NEG. SEQ. CURRENT MIN
2B0D
NEG. SEQ. CURRENT MAX
2B0E
AVERAGED GEN. LOAD MIN
2B0F
AVERAGED GEN. LOAD MAX
2B10
HOTTEST STATOR RTD MIN
2B11
HOTTEST STATOR RTD MAX
2B12
HOTTEST BEARING RTD MIN
2B13
HOTTEST BEARING RTD MAX
2B14
AMBIENT RTD MIN
2B15
AMBIENT RTD MAX
2B16
RTD #1 MIN
2B17
RTD #1 MAX
2B18
RTD #2 MIN
2B19
RTD #2 MAX
2B1A
RTD #3 MIN
2B1B
RTD #3 MAX
2B1C
RTD #4 MIN
2B1D
RTD #4 MAX
2B1E
RTD #5 MIN
2B1F
RTD #5 MAX
2B20
RTD #6 MIN
2B21
RTD #6 MAX
2B22
RTD #7 MIN
2B23
RTD #7 MAX
2B24
RTD #8 MIN
2B25
RTD #8 MAX
2B26
RTD #9 MIN
2B27
RTD #9 MAX
2B28
RTD #10 MIN
2B29
RTD #10 MAX
2B2A
RTD #11 MIN
2B2B
RTD #11 MAX
2B2C
RTD #12 MIN
2B2D
RTD #12 MAX
2B2E
AB VOLTAGE MIN
2B2F
AB VOLTAGE MAX
2B30
BC VOLTAGE MIN
2B31
BC VOLTAGE MAX
2B32
CA VOLTAGE MIN
2B33
CA VOLTAGE MAX
2B34
AVERAGE VOLTAGE MIN
2B35
AVERAGE VOLTAGE MAX
2B36
VOLTS/HERTZ MIN
1, 2, 3
See Table footnotes on page 6–33
GE Multilin
RANGE
0 to 999999
0 to 2
1 to 4
1 to 1000000
0 to 42
0 to 42
0 to 42
0 to 42
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
0 to 2000
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
–50 to 250
0 to 150
0 to 150
0 to 150
0 to 150
0 to 150
0 to 150
0 to 150
0 to 150
0 to 200
489 Generator Management Relay
6.3 MODBUS MEMORY MAP
STEP
UNITS
FORMAT
1
h
F12
1
F115
1
F50
1
h
F12
1
F127
1
F127
1
F127
1
F127
× FLA
1
F3
1
× FLA
F3
× FLA
1
F3
× FLA
1
F3
1
× FLA
F3
× FLA
1
F3
× FLA
1
F3
1
× FLA
F3
1
%FLA
F1
1
%FLA
F1
1
× FLA
F3
× FLA
1
F3
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
× Rated
1
F3
1
× Rated
F3
× Rated
1
F3
1
× Rated
F3
1
× Rated
F3
× Rated
1
F3
1
× Rated
F3
1
× Rated
F3
× Rated
1
F3
DEFAULT
0
0
16
1000
0
0
0
0
0
125
0
125
0
125
0
125
0
100
0
125
0
200
0
200
0
70
0
200
6
0
200
0
200
0
200
0
200
0
200
0
200
0
200
0
200
0
200
0
200
0
200
0
125
0
125
0
125
0
125
0
6-29

Advertisement

Table of Contents
loading

Table of Contents