Gathering Cooling Related Information (Overview) - HP Integrity Superdome 2 16-socket Service Manual

Hp integrity superdome 2 user service guide
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

UID: Off
Powered: On
Diagnostic Status:
IOX enclosures
Use the show IOX power all command to gather information on IOX enclosure power:
sd-oa1> show iox power all
IOX 5:
No IOX Installed
IOX 6:
No IOX Installed
IOX 7:
No IOX Installed
IOX 8:
No IOX Installed
IOX 9:
Present Power: 189 Watts AC
IOX 10:
Present Power: 222 Watts AC
IOX 11:
No IOX Installed
IOX 12:
No IOX Installed

Gathering cooling related information (overview)

Use the following commands to gather all complex cooling information:
show enclosure fan all
sd-oa1> show enclosure fan all
Fan #1 Information:
52
Troubleshooting
Internal Data
Management Processor OK
Thermal Warning
Thermal Danger
I/O Configuration
Power
Device Failure
Device Degraded
Status: OK
Speed: 60 percent of Maximum speed
Maximum speed: 18000 RPM
Minimum speed: 10 RPM
Power consumed: 32 Watts
Product Name: Active Cool 200 Fan
Part Number: 412140-B21
Spare Part Number: 413996-001
Version: 2.9
Diagnostic Status:
Internal Data
Location
Device Failure
Device Degraded
OK
OK
OK
OK
OK <<<
OK
OK
OK
OK
OK
OK