GE SHOWBIZ Brochure page 41

General electric stage, studio, disco and photo graphic lighting brochure
Table of Contents

Advertisement

Discharge lamps
continued
200 Watt CID Hot-Restart Lamp Circuit Diagram
10A
HBC/MCB
Fuse
Ballast G53398. T
L
Sw
1 2 3 E
SG
Irem
220/250V
Biassed Off
AD312/R
50Hz
PFC
Igniter
Supply
35 F 250V
R-100
GC2382
2.5W
HT
HT
C-1 F
12kV
250V
Output
N
Sw - Normally open contacts - Manual switch or 2 second ON timer
Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
76
GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE
400 Watt CSI Lamp Circuit Diagram
13A
HBC/MCB
200W CID Lamp
Fuse
Ballast G53371 .T
Ref 99-0211
L
G53444 or
220/250V
Bag Turgi
50Hz
PFC
SE 15/7U
Supply
40µF 250V
Igniter
R-100
2xGC2331
2.5W
C-0.47µF
250V
N
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
575 Watt CID Lamp Circuit Diagram
16A
HBC/MCB
Fuse
L
400W CSI
Ref 99-0201
220/240V
B
Lp
50Hz
9kV
N
Supply
80 F 250V
4xGC2331
N
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Ballast Irem ZA57
575W CID Lamp
Ref 99-0415
G53444 or
B
Bag Turgi
9kV
Lp
PFC
SE 15/7U
N
Igniter
R-100
2.5W
C-0.47 F
Lampholder
250V
Bender & Wirth
933/1419
1000 Watt CSI Lamp Circuit Diagram
20A
HBC/MCB
Fuse
Ballast G53307. T
L
1000W CSI Lamp
Ref 99-1222
or 99-0221
G53444 or
220/240V
B
Bag Turgi
9kV
Lp
Lamp
50Hz
PFC
SE 15/7U
N
Supply
175µF 250V
Igniter
7xGC2346
N
Lampholder for 99-1222 - Bender & Wirth 938/223 and for 99-0221 - Bender & Wirth 933/1419
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Replace G53445 (or Bag Turgi SE600/D) igniter sparkgap element when replacing a failed lamp