Measurement Execution - Panasonic LightPix AE20 User Manual

Table of Contents

Advertisement

Even if you selected X-directional measurement direction in CONFIGURATION mode, Y-directional
base length and the allowable range do not affect the inspection results. Similarly, even if you
selected Y-directional measurement direction in CONFIGURATION mode, X-directional base length
and the allowable range do not affect the inspection results.

4.6.7 Measurement Execution

The ways of mesurement execution
Internal trigger: ON
Internal trigger: OFF
Judged measurement results
The LightPixAE20 outputs these judgement results to parallel ports of OUT1 to OUT3
Judgement results
All OK
Both maximum and minimum are
within the base length +/-value for
judgement base criteria
MAX:OK
Only maximum value is within the
range
MIN: OK
Only minimum value is within the
range
All NG
Both maximum and minimum values
are beyond the range, or the unit
failed to measure a length.
Internal Trigger: Switches ON/OFF in CONFIGURATION mode
Parallel input/output timing chart: Page 102
Measurement is automatically executed by switching to RUN mode.
After switching to RUN mode, input the TRIGGER signal to external devices or
press the TRIGGER button.
OUT3
OUT2
OUT1
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF