Hot-Swappable Components; Hot-Swap Capabilities; Components; Normalized Airflow - Bosch DVA-12T Installation Manual

Iscsi premium series raid subsystem
Hide thumbs Also See for DVA-12T:
Table of Contents

Advertisement

RAID Subsystem DVA-12T | Installation Manual
Event notification messages indicate the completion or status of array configuration tasks and
are always accompanied by two (2) or three (3) successive and prolonged beeps.
CAUTION!
Failing to respond when an audible alarm is heard can lead to permanent damage of the RAID
subsystem. When an audible alarm is heard, rectify the problem as soon as possible.
2.5

Hot-swappable Components

2.5.1

Hot-swap Capabilities

The RAID subsystem comes with a number of hot-swappable components. A hot-swap compo-
nent is one that can be exchanged while the subsystem is still online without affecting the
operational integrity of the subsystem. These components should only be removed from the
subsystem when they are being replaced. At no other time should these components be
removed from the subsystem.
2.5.2

Components

The following components are hot-swappable:
2.5.3

Normalized Airflow

Proper subsystem cooling is referred to as "normalized" airflow. Normalized airflow ensures
the sufficient cooling of the subsystem and is only attained when all components are properly
installed. Therefore, a failed component should only be hot-swapped when a replacement is
available. If a failed component is removed but not replaced, permanent damage to the sub-
system can result.
Bosch Security Systems
Power supply units (PSUs)
Cooling modules
BBU module
Hard drives
Introduction | en
15
F.01U.027.798 | V1 | 2006.06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents