Connecting Electric Dryers - LG Tromm DLEX7177RM User's Manual & Installation Instructions

Dryer with steam
Hide thumbs Also See for Tromm DLEX7177RM:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATIONINSTRUCTIONS
CONNECTING ELECTRIC DRYERS
(cont.)
AWARNING:
• Connect
the power
cord to the terminal
block.
Each colored
wire should
be connected
to
same color screw. Wire color indicated
on manual
is connected
to the same color screw
in block.
Failure to follow these
instructions
may result in a short or overload.
• Grounding
through
the neutral
conductor
is prohibited
for: (1) new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles,
and (4) areas where
local
codes
prohibit
grounding
through
the neutral conductor.
Three-Wire
Connection
for Electric Dryers: Direct Wire
• A 3-wire connection
is NOT permitted on new
construction
after January 1, 1996.
• A UL-listed strain relief is required.
• Use UL-listed 3-wire #10 AWG-minimum
copper conductor cable.
• Allow at least 5 ft (1.5 m) length to allow for
removal and reinstallation of the dryer.
Terminal
Remove 31/2inches (8.9 cm) of the outer
covering from the wire. Strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three wires into a hook shape.
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole;
then thread the power cable
prepared in Step 1 through the strain relief.
Ground
Hot
(Bla
-Neutral
Ground Wire
two hot leads of the power cord
to the outer terminal block screws. Attach
the neutral wire to the center terminal block
screw. Connect the external ground (if
required by local codes) to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.